  1. leur2011

    New Feeder Vertical Section of existing 4.16kV MC Switchgear

    One (1) new 2000A bus, 1200A VCB, 3P, 3W, 60Hz, 50kA, 2sec vertical feeder section will extend each bus of my existing 4.16kV double ended metal-clad switchgear model PowlVac® manufactured by Powell Industries Inc. to feed the two (2) new 4.16kV, 1200A, 3P, 3W, 60Hz, 50kA, 1sec metal-enclosed...
  2. leur2011

    Looped distrbution

    In this system the primaries of distribution transformers form a loop. The loop circuit start from the substation bus-bars, makes a loop through the areas to be served and returns to the substation. The circuit provides for quick restoration of service in the case of transformer or feeder fault...
  3. leur2011

    35 kV GIS Feeder Section?

    Contact the vendor rep of the existing GIS if you know the manufacturer of the equipment. You have to have data sheet and SLD of existing GIS to get conservative quotation of one additional bay unit.
  4. leur2011

    Parallel cables on LV side of a transformer

    Why not use cable bus. Easier to manage for your requirement. See the Link
  5. leur2011

    ATS incoming source 1 & 2 Designation

    Your last paragraph is the present situation of the connection of the two incomer feeder cable of our ATS. We used the emergency generator as normal “N” (preferred) power source-1 of ATS and we used the utility grid as emergency “E” (alternate) power source-2 of ATS base on facility existing...
  6. leur2011

    ATS incoming source 1 & 2 Designation

    Thanks waross, to describe more of my question in my first post, our local standard state that critical security system loads should be supplied by emergency power regardless of how emergency power is defined in NEC or IEEE. My question was if we swap the two feeders does it impact the existing...
  7. leur2011

    ATS incoming source 1 & 2 Designation

    This question is mainly in regards to consequences. I have a 480VAC open transition Automatic Transfer Switch (ATS) to put in service soon; and I'm wondering what happens if we designate single ended 480V switchgear SG-002 fed from existing upstream generators as normal “N” (preferred) power...
  8. leur2011

    Bucket for 3 Phase Power?

    As per our project specification, it state that “Space” – is a switching assembly locations which are not be equipped with a switching device but shall be developed to accept, with no modifications other than the installation of devices within the compartment door, a switching device suitable...
  9. leur2011

    Bucket for 3 Phase Power?

    Thanks jraef, Our vendor offer indicate that space bucket do not have door interlock such that if there is an accident happen due the reason of accessing the space bucket live parts by opening the shutter will void the warranty of their supplied equipment. Does the above statement acceptable...
  10. leur2011

    Bucket for 3 Phase Power?

    For an "SPACE" bucket in MCC, does UL 845 requires to be equip with automatic or manual shutter. Or a cap plugs is suffice to cover the stab opening of vertical bus?
  11. leur2011

    Vacuum circuit breaker sizing

    See below sample of Vacuum Circuit Breaker sizing. While the demand load current is only 335.26 Amps, the selected VCB rating is 1200 Amps. Actual application rating of Vacuum Circuit Breaker depends on the CT ratio and the relay settings. Vacuum Circuit Breaker (VCB) is electrically...
  12. leur2011

    Derating factor for LV Cables - IEC

    Don't confuse the derating factor for multicore cables touching each other (as illustrated in your sketch) with the installation of multicore cables which are laid in several layers on the same tray, I mean does your standard in cable installation allows you to lay low voltage multicore cables...
  13. leur2011

    Derating factor for LV Cables - IEC

    Find below derating factor for Low voltage multicore cables which are laid in several layers on the same tray.
  14. leur2011

    Cable Sizing NEC vs IEC

    1- Ampacity calculation and cable sizing can be as per NEC, or from the tables in IEEE 835, or IEC 60364, and IEC 60502-2. 2- Cable derating factors of ETAP or CYME can be use to calculate ampacities, as an alternative to the NEC, IEC or IEEE 835 tables. 3- Soil temperature is 40°C. The soil...
  15. leur2011

    Contact Rating of 24Vdc Inhibit Transfer Relay

    Many thanks to waross, dpc, davidbeach, rcwilson, & LionelHutz for sharing your expert insight.
  16. leur2011

    Contact Rating of 24Vdc Inhibit Transfer Relay

    @rcwilson, thanks for describing clearly the control operation philosophy. - When you said the lockout relay contacts (with 125VDC coil voltage) to energize the block transfer relay (with 24VDC coil voltage) in the ATS. Would that be OK. The 24VDC coil of inhibit transfer relay in the ATS is...
  17. leur2011

    Contact Rating of 24Vdc Inhibit Transfer Relay

    OK guys hopefully attached diagram is clear by now. Sorry for attaching truncated images. http://files.engineering.com/getfile.aspx?folder=309f8d26-6698-4891-92f1-43d0b9b09204&file=Clear_E1L_Diagram.jpg
  18. leur2011

    Contact Rating of 24Vdc Inhibit Transfer Relay

    I attached clearer picture of the control diagram. When fault occur at feeder CB in SG-002, the 125VDC 86 LOR located at MCC will trip and lockout. The 125VDC 86 LOR will block transfer and re-transfer control operation of 24VDC inhibit transfer relay located at ATS...
  19. leur2011

    Contact Rating of 24Vdc Inhibit Transfer Relay

    The 24VDC contact of relay will melt when block transfer and re-transfer operation of Automatic Transfer Switch due to the trip and lockout in the 125VDC 86 LOR. Would this be the case? waross also pointed out there is issue of differing 24VDC and 125VDC relay coil voltage and failure to clear...
  20. leur2011

    Contact Rating of 24Vdc Inhibit Transfer Relay

    What are the two different issue of relay coil and contact ?