  1. Warhamer

    Modular Steel Construction Rehash Thread

    Bookowski, Each State maintains this modular codes differently. What State would you be looking at? You mention CA which runs the modular programs under Title 25 Chapter 3. There are some exemptions based on size of the final footprint of the build. The program is administered by HCD, which...
  2. Warhamer

    European Steel in US SMRF

    Bookowski, A couple of other quick things I can say to watch for is, most States have a Modular Building Code that is separate from the local jurisdiction. Do to the enabling laws of the Modular Program, modular program's adopted codes control the codes used for the modular construction...
  3. Warhamer

    European Steel in US SMRF

    Bookowski, The simple answer is for prefab/modular construction, yes it can be done. As STpipe and HTURKAK, mention the key role is proving the Steels to ASTM. Depending on where you are going, some US State modular programs straight up require testing to prove ASTM compliance; others are good...
  4. Warhamer

    Liability / Re-use Fee for Factory-Built Housing

    SIPengineer, having been in the Factory Assembled Housing/modular/off-site construction (ICC likes off-site construction) industry for 10+ years, I keep reading some things that raise flags for me, so just going to toss out a couple of points as food for thought. I have been on the...
  5. Warhamer

    Engineer's Duty to Respond to the AHJ

    phamENG, You mentioned the building is factory built. Is it subject to the VA industrialized building regulations? Depending on where the trusses are installed they could be covered under the compliance agencies review, represented by the third party label and VA state label, and not the...
  6. Warhamer

    Sprinklers? Industrialized Building (Modular) with New Metal Building Enclosure

    NOLAscience, the State Fire Marshal office will be your best place to go, I do not have information on how they are treating shipping containers yet in LA. SFM Rules regulations: http://sfm.dps.louisiana.gov/ib_info.htm LA State Uniform Construction Code Council...
  7. Warhamer

    Sprinklers? Industrialized Building (Modular) with New Metal Building Enclosure

    My first suggestion is get with the AHJ/SFM see what they want. Gulf Coast, narrows down the States involved, and some of them do not play well with unregistered buildings. Each State will have a list of approved TPIA's. They also have different rules when dealing with unregistered buildings. If...
  8. Warhamer

    Sprinklers? Industrialized Building (Modular) with New Metal Building Enclosure

    NOLA on your item #1 On the modular buildings, definitely need to get the SFM and AHJ involved. Gulf Coast and off shore use narrows down the potential State Modular Programs. In the past some State Modular Programs have told an owner with unapproved modular buildings to reach out to an...
  9. Warhamer

    Sprinkler Test Gauge Requirements

    For this the quality control process has to determine that the piping is installed properly (meets approved plans) and that it holds pressure with no leaks at the time of final assembly at the manufacturing facility. The test here will have no bearing on final acceptance and operational testing...
  10. Warhamer

    Sprinkler Test Gauge Requirements

    Test pressure, I am not aware of right at this moment. Fielding a question from one of the inspectors I work with. The concern was if there were guidelines for test gauges similar to plumbing codes, where test gauges must have incremental marks of 2 psi or less on gauges over 100 psi. The...
  11. Warhamer

    Sprinkler Test Gauge Requirements

    I have been passed a question if there are any requirements on test gauges for sprinkler pipe testing. A building manufacturer wants to test the sprinkler piping installed in their facility before it leaves, to make sure the piping does not leak and holds required pressure before it reaches the...
  12. Warhamer

    IBC and international codes

    Check the Reference Standards in Chapter 35 for any Amended edition of the IBC you might be using. That will tell you what is to be expected by the Local Building Official. While it is called the "International" codes, it is generally North American and US centric on the Reference Standards. The...
  13. Warhamer

    PEB - Certification Requirements for Manufacturers in Texas

    Structengr23, TDLR and IHB, has some very generous rules on what is an IHB. A large number of the Electrical Equipment Shelter Manufacturers and Electrical Equipment Integrators in Texas have recently been finding out they are required to sign up with TDLR and IHB. With the information you...
  14. Warhamer

    Is it allowed for a pipeline of fire water and electrical conduits to pass through the same opening?

    Eduardo, I would start with 110.26 and its subsections in the NFPA and look at the dedicated space provisions. That is the section I would be using if this was in a project I was reviewing. EIT, Modular Building Industry
  15. Warhamer

    Wood modular classroom roof structure

    Haydenwse, Sorry, I got caught by the eng-tips loading error and just now got back in to the website. The best way to tell would be to run capacity checks using the APA H815 equations on the new span condition. The other way I have seen done, is having LVL retrofits done. EIT, Modular...
  16. Warhamer

    Wood modular classroom roof structure

    Haydenwse, Generally Data Plates and labels are located on or near the Electrical Panel Cover. Other common locations is to have them in a closet, or above a drop ceiling on the hitch end. Again depending on age of the building, and what State this was manufactured for, the labels and Data...
  17. Warhamer

    Wood modular classroom roof structure

    Haydenwse, What it sounds like from your description is a Plywood Ridge Beam. These are not uncommon in Classroom units. APA has a design standard for these in H815. Check your column locations as I have seen very few Ridge Beams span the full length of a unit (unit = single module). The ridge...
  18. Warhamer

    16 Gage Staples

    ESR-1539 Also will have staples for Diaphragm and Shearwall Values. Bostitch is a listed in ESR-1539. EIT, Modular Building Industry
  19. Warhamer

    2012IBC Table 601 footnote b.

    Zeeko, I would read this as follows: 1) Your A-4 Occupancy would require a fire-rated ceiling/Floor assembly if the height is less than 20 feet above the floor below. 2) F-1, H, M, S-1 uses would always be required to have a fire-rated assembly with duration as indicated by the table. EIT...
  20. Warhamer

    "Struware - Code Search" Software reviews

    The software finds some use with Modular Buildings. From use and review, it does well for your "simple" buildings. When checked against hand calculations usually I am only seeing a difference to a tenth of a psf. It has tabs for Wind, Snow, and Seismic. Other tabs include seismic anchorage for...