  1. MechCC

    Repair on vessels with PWHT

    I mean if we need to remove the HT stampe on the Nameplate and if we need to re-register with ABSA.
  2. MechCC

    Repair on vessels with PWHT

    Hi all Can anybody help with my question below: If Sec 8.1.6.4.2 (Preheat or Controlled Deposition Welding Methods as Alternatives to Postweld Heat Treatment) of API 510 was followed instead of doing a PWHT for a repair on a vessel that was originally stress relieved, will it change the...
  3. MechCC

    PWHT

    No it is not stamped "UB". But the vessel is a steam separator.
  4. MechCC

    PWHT

    Thanks metengr. Per UW-2, PWHT is required for vessels used for lethal services. Is steam considered lethal service? I assum the PWHT was done on the vessel at the beginning because of the thickness. If that is the case, I think we don't have to follow Note (c).
  5. MechCC

    PWHT

    It is a butt weld. And it is P1 material.
  6. MechCC

    PWHT

    Hi all, We are going to replace a 3" flange for a vessel (Designed to Sec VIII Div 1). The vessel was PWHT and it was used for steam service. The nozzle thinkness is 0.6". Per UCS 56 SEC VIII Div 1, PWHT is not required for thickness less than 1 1/4". Is PWHT required for this repair? Thanks,
  7. MechCC

    How suction/discharge check valve works for recip pump and diaphram pumps

    Thanks LittleInch. So that means if the pressure discharge piping is close to zero, then the discharge pressure of the recip pump will be close to zero? If so, how can the discharge pressure build up at the discharge?
  8. MechCC

    How suction/discharge check valve works for recip pump and diaphram pumps

    Hi all, Is the suction/discharge check valve for recip and diaphram pump opened by the differencial pressure across the valve? Will the discharge pressure be affected by the suction pressure? Thanks,
  9. MechCC

    Trim 12 for steam service

    The pressure/temperature is 7826kPag at 296degreeC. Thanks.
  10. MechCC

    Trim 12 for steam service

    Hi, Does anybody know if Trim 12 can be used for steam service? Thanks,
  11. MechCC

    Pipeline Corrosion Coupons

    Thanks BigInch. Do you mean CSAZ662 requires corrosion coupon for all pipelines?
  12. MechCC

    Pipeline corrosion coupon

    Hi all, Can anybody tell me if corrosion coupons are required for all the pipelines per CSA Z662 or other codes? Thanks,
  13. MechCC

    Pipeline Corrosion Coupons

    Hi all, Can anybody tell me if corrosion coupons are required for all the pipelines per CSA Z662 or other codes? Thanks,