Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. kirei17

    Question on Crane Runway Girder Design

    Thanks for the quick reply. 1. Okay i got it. That's why i'm a bit in doubt with the design example in question because it divide the load equally to every wheel point of the crane (that's 2 x 2, 2 wheels on each end). I agree with your "100%" take as a conservative approach. 2. I'm aware the...
  2. kirei17

    Question on Crane Runway Girder Design

    Hi, I Initially searched for a topic related to my question (this exact question has been asked before), but it is closed now. So, i decided to create a new one. Here's the question. In AISC Design guide 7 Industrial Building Design 3rd edition, about design of crane runway girder example...
  3. kirei17

    A Question Regarding Mononobe Rain Intensity Theory

    @1503-44 And? I'm aware of this. Why i said linear comes from the result from Mononobe theory itself. Please read again this passage "if this rain extend for 24 hour then the amount of rain is 0.042 x 24 = ~ 1". If 0.042 is a peak value, then the R24 can't be unity (1), it'll fall below that...
  4. kirei17

    A Question Regarding Mononobe Rain Intensity Theory

    HI! This is probably just a simple question. I have a question, i hope someone has the answer quickly in mononobe rain intensity equation, we have I = R24/24 x (24/t)^ (2/3) if i take R24= 1 unity, i have an intensity of 0.347 R24 if duration of rain is 1 hour and 0.042 if duration of rain is...
  5. kirei17

    Bolt's Number of Slip Planes

    Hi, I am simply thinking of the factor ns in the calculation of resistance limit in AISC J.3.8 slip-critical bolt for high strength bolts. As one of the factor for determining the value R, ns or number of slip planes (in some articles it is mentioned as equal to shear planes), is a significant...
  6. kirei17

    V-ditch design

    Aeolian, Really late response. But thanks for the explanation. I didn't see the positive negative sign before. So the limitation is -30 degree. For bigger negative slope, it is considered near flat so no need to calculate for thickness of wall (if wall is even required).
  7. kirei17

    Further Question on Side Blowout

    thread507-297453 Hi, I'm referring to the old there above, Still referring to ACI 318-05 appendix D. Sure there's a new one, but let's just say i can not access the 08 version (or even newer one, if it does exist). So i'm still confuse with the formula in ACI D.5.4.2, which says, as below...
  8. kirei17

    V-ditch design

    Aeolian, Thanks! I have found your recommendation, and at a glance it's quite a handy complete handbook. Lots of graphics etc. Anyway, i still can't find the graphic for sloping wall surface lateral pressure. There are some, but the slope is in reverse side, rather than the slope that i want...
  9. kirei17

    V-ditch design

    Hi, I'm curious about soil pressure design for V-ditches. What i have been thinking is that there must be a difference for lateral soil pressure if the surface is sloped than when it is vertical (no slope). This thinking of V-ditches should not be a concern if you are imagining sideway ditches...
  10. kirei17

    Moment on Mat Foundation

    SteelPE, no, no, i already remembered about the sudden change (it's a point moment, point force hence sudden drop). How the heck could i miss that? Of course your diagram is true. I don't do much of this kind of thing anymore since university. By the way, the new diagram is not new. I only scan...
  11. kirei17

    Moment on Mat Foundation

    Now if the combined moment shape should look like the one that you sent, that means in my previous attached drawing (re-attach below for scanned, better quality drawing), my assumption of normal condition (normal operation vertical load) is false. Because if it is true, then the combined moment...
  12. kirei17

    Moment on Mat Foundation

    Thanks SteelPE :D Now i see why it is being called bow-tie. But its different from what i am expecting. Actually my diagram is not far from what you shown, but mine didn't have sudden drop (change of sign) at the point of application of conc moment (it's like the drop in shear diagram?). Maybe...
  13. kirei17

    Moment on Mat Foundation

    Wait a minute. How to merge or edit a post?? Im new to this forum, so pardon me for multiple reply. Sorry, i misinterpret the bow-tie shape. Now i think it is different with my understanding of moment diagram, but i still think that my assumption is the correct one. How could the moment at the...
  14. kirei17

    Moment on Mat Foundation

    To further explaining, actually my objective here is to know in what part of section should rebar lap splice be placed. So it would not be placed at the section with maximum tension but at minimum tension.
  15. kirei17

    Moment on Mat Foundation

    Sorry, perhaps i wrote it falsely. Of course in one section when there is negative moment at one side (whether it is top or bottom), there is always going to be positive moment at the other side, and so does the opposite. But from what i learned is that moment diagram only show the tension...
  16. kirei17

    Moment on Mat Foundation

    about the concentrated moment, i dont get it, bow tie has max positive and max negative in one section. How can that be possible? I thought mine is already correct looking at the possible bent form of the foundation.
  17. kirei17

    Verification of allowable soil bearing capacity

    soil bearing capacity? i get the impression that your design is shallow foundation. shallow foundation is related heavily to the soil types below the designed area and the width and depth of foundation and groundwater level. i usually get troubled if it is multi-layered as it requires an extra...
  18. kirei17

    Moment on Mat Foundation

    Hey, Here is just a simple question (but i believe the answer would be very critical). I just want to know if my assumption of moment diagram is correct. My case is a mat foundation. Here i just drew it two dimension. I showed column as a load only, while for the foundation i drew it exactly as...
  19. kirei17

    Stainless Still Anchor Washer

    I have further asked some practical people about this matter. Someone recommended me DIN 125. So round washer in SUS 316 does exist, but not in ASTM. Currently googling DIN 125. Does anyone here know, what type of application DIN 125 washers are subject at? Is it applicable to use as round...
  20. kirei17

    Stainless Still Anchor Washer

    Thanks Ron, It is a 4-leg LNG vaporizer with only one anchor for each leg, so i assume it could be cast-in-place. Though, having a template before setting out the anchor prior to pouring would be a nice idea. I have just asked portland bolt, and the answer is that no ASTM specification exist...
Back
Top