Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. mike20793

    ASCE 7-10 section 4.5.3 Vehicle Barrier

    Chapter 4 loads are service so you need to factor them appropriately based on your design methodology. I'm not aware of any material allowances for stress increases.
  2. mike20793

    W-Shape column on CMU wall corner

    Concrete blockout with embed plate is the easiest (for engineers). What magnitude is the reaction?
  3. mike20793

    Reinforcing a W section for Torsion.

    I don't think the torsion will ever be resolved into the HSS tube unless it engages both the top and bottom flanges. You could weld continuous plates to close the wide flange shape; it may be your best bet.
  4. mike20793

    ASCE 7-10 12.2.3.1 - Townhomes

    Can you not use the IRC instead of IBC? It may help you out to stay in there instead of going to the IBC and ASCE 7. I have never used the exception and would be hesitant to since the gyp board really doesn't give much of an inelastic behavior before failure. Also, what is the demising wall...
  5. mike20793

    SBEDS 4.2

    You're not going to find that spreadsheet available and I doubt anyone is willing to share it since it requires DoD clearance to get access to the newer versions. Your best bet is asking Protection Engineering Consultants. They wrote the spreadsheet and pretty much the entire blast code for UFC.
  6. mike20793

    Beam To Beam Moment Connection ??

    That's true dik, but I agree with WARose. Most often the plate will cause a conflict with top of steel and composite deck or joist bearing or something else that's usually not worth coordinating out. If you can make the plate work, by all means do it, but in my area, the common detail is all...
  7. mike20793

    I Beam Reinforcing Question

    Where in the span are they trying to do this? At first glance, that fix doesn't look like it would cut it. I wouldn't let them cut my flange like that, even at the end of the beam near supports. You could check the remaining section as a WT and strengthen based off the extra strength but I would...
  8. mike20793

    Beam To Beam Moment Connection ??

    I'd want all my weld thrus to be complete pen welded, even if something else would work. Use the plate if you can, but complete pen weld thrus are common in my area.
  9. mike20793

    Angle Support Design for Uniformly Distributed Dead Load

    I'll add that there is a special case for equal leg angles that simplifies the calculations.
  10. mike20793

    Building Code Load Generation Software

    I agree with Koot. My old, larger firm had their own in house spreadsheets but my new, much smaller firm uses Code Search and I like it. It functions well, fucntions accurately, and is accepted for calculation submittals. I also get a lot of use out of the dead load calculators.
  11. mike20793

    Risk Category - Building Addition

    Expansion joint or hard attaching to existing? If expansion joint, I vote Risk Category II since they are essentially separate structures. If hard attached, then Risk Category III.
  12. mike20793

    Design of Plywood over Square Hole?

    XR250, thanks for adding that.
  13. mike20793

    Design of Plywood over Square Hole?

    The span rating of plywood is how far it can span under 100 psf load.
  14. mike20793

    ASCE 7 Wind Loads Force Location

    Think about it.. you're applying a pressure over a fixed area so where would the resultant need to be? At the centroid of the area. If you have a diaphragm and a floor above, then to calculate the force at the level, you would use the tributary width/height of half the floor above and half the...
  15. mike20793

    Girder Truss Boundry Condition

    I would model the columns and pin everything. A vertical roller at the top chord isn't quite accurate because the column prevents it from moving horizontally. The column will rotate some in bending from the couple from the chords, so you will want to capture that in your model.
  16. mike20793

    Coldform / Gypsum Shear Wall

    I've had good success with the Sureboard product. It's steel lined gyp board. I have used it on several east coast seismic projects.
  17. mike20793

    Re-entrant corner at alcove

    Why not put a joist at each end of the alcove and let it function as a drag strut? I usually look at these types of cases as semi rigid so those walls don't suck up an unrealistic amount of lateral load.
  18. mike20793

    Precast Channel Slabs(roofing)

    Do you have a picture of the cross section or the plan callout?
  19. mike20793

    Removing interior columns in an existing PEMB

    I agree with hokie.. beware of this one. If you are going to analyze this from square 1, then it is likely not going to be economical for you or the building itself.
Back