  1. strucEng36

    Mezzanine inside Tilt up Building - Lateral Stability (Seismic)

    can you please advise where is this provision in CSA standard
  2. strucEng36

    Joints in SAP2000

    You may look into joints restrains assign in SAP
  3. strucEng36

    SAFE Isolated Footing Analysis and Design

    There is an icon on the left side of default settings program window, its no.11 if you started counting form top left going down "Draw Design Strips"
  4. strucEng36

    SAP2000 Expansion Joint Modeling?

    Could you clarify what shear transfer you have to model? It will help to better answer your question Have a look at this one too https://www.youtube.com/watch?v=2xh4gRX9_A0
  5. strucEng36

    Connection between the floor slab and RCC wall.

    To my knowledge the thickness of the slab near the connection is determined by satisfying the applied flexural, one way and two way shear stresses as per the applicable code combinations. Now, if your concern is seismic loads, you should indicate the LFRS and the design code you are using. In...
  6. strucEng36

    Obtaining centre of rigidity in Etabs

    If you are referring to user loads you may find the eccentricity field on your bottom right corner when you hit modify load pattern If you meant code static loads it should be on the top left corner
  7. strucEng36

    Conduits through Stud Rails

    Their software does not show any message or warring once height is more than conventional. I would guess that it will do so if it was limited to standard heights.
  8. strucEng36

    Differential Settlement of two adjacent structures

    Thank You for the valuable input Is there any other consideration in this case I should account for ?
  9. strucEng36

    Differential Settlement of two adjacent structures

    Thank you very much for the valuable input why is this case specific load calculation would be needed if the footings have similar pressure Generally in clay the increase of least width of footing will decrease the bearing capacity? As the report mention maximum least width to be 6 m and...
  10. strucEng36

    Differential Settlement of two adjacent structures

    As per the enclosed sketch I am working on steel moment frame structure resting on clay soil attached attached to concrete tower resting on rock Both structures will be based on shallow isolated footing with no tie beams. The soil report provided allowable bearing to be 125 kpa The report...