  • Users: ViCH
  • Order by date
  1. ViCH

    Diesel Standby Generator - Life Expectancy

    If You mean 50 years with replacing all spares and maintenance as per run-hours only - then NO. You will get big troubles already after 2-3 years of operation. Its many spares and maintenance services that You have to do either by run-hours or by standby time if its standby unit. You should...
  2. ViCH

    lithium ion batteries

    Its strongly recomended not to discharge fully LiOH or Li-ion cells. Usually controllers for such batteries are smart enough to keep proper float charge voltage, so it is no reason to keep your device discharging, just for preventing overcharging. Full discharge will decrease your battery...
  3. ViCH

    AVR Basler DECS200(redundancy), VARs moving

    Thanks for response, Mikel. I think, they just design it only for running in parallel.. So base load was using as a temporary mode, while genset was syncing to gas turbine generator (MAIN SUPPLY). Then, once breaker for GTG open, second diesel sync with first, and DEIF switchs to Load sharing...
  4. ViCH

    AVR Basler DECS200(redundancy), VARs moving

    Hi again.. This DEIF GPC2 controller... I have rechecked drawings and found interesting thing. It has modes for governor (fixed F, base load, droop, load sharing), and for AVR (fixed V, fixed VAR, fixed PF, VAR sharing).. By drawings, its always fixed voltage modes for both engine. For governors...
  5. ViCH

    Need 18V 1.5 amp motor having 200-400 maximimum RPM

    Ed, he looking for NO gearing Viktor Electrical Technician II
  6. ViCH

    Diesel engine can not give more than half load

    That governor 723plus has jumper on terminals 9-10. This terminals is for LOAD SHARING SIGNAL. I have checked many manuals of Woodward 723+, but didnt found purpose of jumper. If i do not need load sharing, should it be jumped or remained open? Viktor Electrical Technician II
  7. ViCH

    Diesel engine can not give more than half load

    Well, genset is discussed one, and loads - a lot of 400V UPS, motors, any domestics.. Plus 11KV 250KW air compressor motors. We need at least 2 unit running. Due to our frequency dropping too high, usually when we start second big motor, we getting underfrequency trip. So our practice now, we...
  8. ViCH

    Diesel engine can not give more than half load

    I mean best combo for stability during dynamic loads switching ON. Viktor Electrical Technician II
  9. ViCH

    Diesel engine can not give more than half load

    Thanks for links and file! I have read it before, and now understand separate functions of droop and iso, but what is the best combo for single genset? And what is the best combo for 2 parallel gensets? Just refer to your experience. Without grid. Viktor Electrical Technician II
  10. ViCH

    Diesel engine can not give more than half load

    One more question, how engine perform: 1) If AVR and Governor in Droop mode 2) If AVR no droop, and Governor Droop 3) If AVR droop, but Governor not. Is it major changes will be? Viktor Electrical Technician II
  11. ViCH

    AVR Basler DECS200(redundancy), VARs moving

    Thanks Mikel, for sharing Your experience. I think we stop here, since I heard the possibilities, but cannt check it on practice. At least next time I will know what to do. Viktor Electrical Technician II
  12. ViCH

    Diesel engine can not give more than half load

    I agree. Today my last night shift, after 2 weeks I am going to day shift, and my goal will be to get approval for load test. Anyway, I have learnt much during this troubleshooting, thanks for You all! Once any update or results, I will write here. Viktor Electrical Technician II
  13. ViCH

    AVR Basler DECS200(redundancy), VARs moving

    DEIF Multi Line 2. It was using for constant control of parallel work two gensets, without grid. DECS was AVR mode with 3% droop. Now I dont have access to them (however I still keeps docs and reports of it), but I just wondering to know was it problem, or no. It was "my small frog, which I had...
  14. ViCH

    Diesel engine can not give more than half load

    MAP sensor we checked, its working well on different pressures. Do you think 5 point is must, if this two configure lines shows: CONFIGURE: Z10: CFIG OPTION.USE 5-GAIN MAP 0 CONFIGURE: Z10: CFIG OPTION.USE CONST DYNAMICS 1 BTW, today we did no-load testrun with open port of turbocharger inlet...
  15. ViCH

    Generator frequency jumping on 50%+ load

    BTW, should AVR be in same droop mode, as governor? How it can reflect to load efficiency, if for example AVR has no droop, but governor is 4% droop? Viktor Electrical Technician II
  16. ViCH

    AVR Basler DECS200(redundancy), VARs moving

    So its normal that it suddenly happen? Because after start up it was shared VARs correctly several days. Viktor Electrical Technician II
  17. ViCH

    AVR Basler DECS200(redundancy), VARs moving

    I think this question is special for Mr.Catserveng, as he is a super specialist for this AVR model, as I notice. We had situation long time ago, with two same size genset running, equipped DECS200. After few days of stable running, VARs from one generator moved to another, and we got...
  18. ViCH

    Ground fault protection for HVAC

    Big industrial refrigeration compressors very likely to get short circuit, due to icing on motor body and on terminal box. It happens usualy if your freon low pressure drops, but not yet trip. If you dont want to loose whole distribution switchgear at that ground fault moment, better provide to...
  19. ViCH

    Diesel engine can not give more than half load

    Turboateng, yes You are right, it is thermocouples, not thermistors. I just wrongly named it. K type. Viktor Electrical Technician II
  20. ViCH

    Governor plc issue

    You do not have any replays, maybe need to add some more useful info? What is the spec of generator? What is the load on the line and busbar during sync? How it share the load? Did you try move load to generator, before switching off the grid? Viktor Electrical Technician II