Hi there pohbah,
I wouls also like the a general print out of the same acme thread as an example.
I would also like to enquire uf you know of a company in Scotland who sells workshop machining equipment, i.e. Lathes, millers, horiz/vert borers, slotters (all non CNC), lapping machines, etc? I...
Bensley
I always used a pneumatic operated Williams Pump,diaphragm type or PD pump (piston) for corrosive or non corrosive chemical application, there are a few models to choose from, low and high pressure, but only low flows, being suitable for many injection projects.
Totally reliable almost...
The best answer to your material problem is GRE pipe used to be called WAVIN?
This is a glass reinforced epoxy pipe with no flange bolting only "O" rings and keys to lock the pipes together, pressure is not a problem. The pipe runs have to be accurate as the pipes come pre-lengths for...
Can anyone tell me the possible and full content requirement of a Corrosion(Carbon Dioxide) Survey(Scope of Work) in a proposed new offshore gas injection project? Using reciprocating compressors and water cooling ect.
To INCLUDE?
a)Pipe & Fitting & Bulk Material, b)Cathodic Protection, c)Gas...
Naturally the behaviour of the fluid to be sealed at low temperatures must be considered. They are mostly a question of liquified gases. Due to the existance of large temperature gradients when operating at low temperatures, thermal distortions must be kept as low as possible by the use of...
Has anyone had any experiences with outer cylinder head bolts breaking or shearing on a gas recip compressor and the many possible reasons?
Like liquid slugs, loose bolts, cylinder head stud bolt not being installed properly, (bottomed out and torqued) metal fatigue, embrittlement etc?
The gas...
Has anyone ever come accross a blind installed in a PSV process gas relief line to a flare header, as a means of isolating a PSV in a double sited PSV system?
There are no isolation valve fitted in either of the discharge sides of the two PSV valve only the blind in the closed position in the...
I need assistance on Siesmic Loading-Vortex Shedding & Vibration regarding Storage Tanks and piping installations?
1)What is the Natural Vibration Frequencies of Line Pipes ranging from 3" to 16" sch 40 pipe on pipe supports at 6Mts, 7 Mts. and 8 Mts spacing? (Is there a chart...
Can anyone tell mw where to find a good check list or a printable form, of milstones also certificated requirements (Certyfying Agent like Lloyds ete.) in a capital expenditure project?
Ken078
You can purchase the ASME B1.1. 1989 anywhere on the web site?
The Unified Inch Screw Thread document, I have which part or point do you wish to be clarified.
Can I be of assistance to you?
regards
Bensley