Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. rammeda

    Moving to Teamcenter

    1. It looks like Teamcenter environment is not setup properly, try setting up the following variables manually before running the program IMAN_ROOT IMAN_BIN IMAN_DATA then call %IMAN_DATA%\iman_profilevars.bat 2. You need to run ugmanager_import.exe tool with a mapfile to import dwg files...
  2. rammeda

    can't open or run NX6

    Many things can cause this error, did you install latest QRM and MPs? may be you can try re-installing the whole package. Let us know how the problem was solved after you find the solution. Ram
  3. rammeda

    Save Drawing CGM Data

    Hi BOPdesigner, 'Save Drawing CGM Data' Save option only works in Teamcenter, which will generates a .qaf file, do you see .qaf file under the namedreferences of your UG NX dataset for which you generated a CGM with the Save option turned on? if yes, the CGM file was generated successfully and...
  4. rammeda

    Can we automate the logging into teamcenter application>>my navigator

    Small correction to above post, TcEng's user name and OS's user name should be the same, password need not to be. Thanks Ram
  5. rammeda

    Can we automate the logging into teamcenter application>>my navigator

    for 2-Tie implementation of Teamcenter 2005SR1; 1. Add "enableAutologin=true" to each site_specific.properties. 2. Add IMAN_auto_login=TRUE to system preference via "Edit"-"Option" menu. 3. Make sure that TcEng's user name and password same as OS's user name and password. Ram
  6. rammeda

    Part attributes

    A simple UGOPEN program can be developed to remove all part attributes and perform save action for all the files in a given folder. Ram
  7. rammeda

    Moving from TeamCenter

    Hi 2SRPE, Use ugmanager_export.exe utility from Siemens (located in UGII folder) to export the data from TcE to native system. please go through the switches/arguments for this command, especially if you are using revision rules with either date or unit effectivities in Teamcenter, other wise...
  8. rammeda

    IGES & STEP translator set up

    Hi dcar11, "Translator image not found" means either NX translators were not installed or incorrectnly installed, by default NX transaltors are not installed with NX setup. They have to be installed seperately, try re-installing translators from NX3 disk. Ram
Back
Top