Search results for query: *

  1. hillimonster

    AB SMCB contact blocks

    I am answering my own question upon receiving the contact blocks. The 800T version can have only 2 - 800TC-XD4S on the same operator with additional contact blocks on the next level. The 800F version is not capable of having any additional blocks on the second level.
  2. hillimonster

    AB SMCB contact blocks

    Does anyone have any experience with the Allen-Bradley, Self Monitoring Contact Blocks (800TC-XD4S)? I was trying to determine if I could use 2 of these blocks on 1 800T operator along with 2 additional (regular) contact blocks. Thanks,
  3. hillimonster

    PanelView 300 Programming

    i do the USB to Serial as well.
  4. hillimonster

    migration from AB to Siemens

    I agree with Spook6869 (see above) as far as ease of use for Siemens. I have used AB forever and ocasionally get asked to use Seimens s7-300. I think the addressing is confusing, especially when talking over profibus. The fact that you can only monitor one Function Block at a time. You can't...
  5. hillimonster

    RS 500 major error fault

    I have seen, over the last 20 years, the PLC rack can have some problems with the backplane circuit board. I have had this kind (maybe not exact) of fault, probably twice. The circuit board was "flexed" and I assumed the connections were intermitent.
  6. hillimonster

    Analog output 0-30VDC

    I thought I would give an update to my solution, as it is now installed and running, for some time now. (delays by others, as usual!!!). I bought a Instek GPS-S table top power supply that could supply 0-30VDC @ 3Amps. The key to it was that it had a slave mode, which could accept a Analog...
  7. hillimonster

    Analog output 0-30VDC

    Sorry for the long delay in response. I am trying to get a variable output to a Valve device that is stepped from 1 Volt to 30VDC over time. So my PLC Analog Output drives a device that can vary (from an analog signal) for 1 - 30VDC @2.5 Amps max Load. PLC outputs can't drive this kind of power...
  8. hillimonster

    Analog output 0-30VDC

    With a PLC is it possible to get analog outputs of 0-30VDC @ 1.0 Amp max? It looks like the PLC analogs outputs go from +/- 10VDC. Does anyone know of a way to get a variable controlled analog from a PLC (possibly through another device) to get this kind of control. Thanks
  9. hillimonster

    micrologix 1500 and RSLinx communication error

    I have had this problem as well. The USB convertor does work (brand Keyspan), but the Auto config does not. You have to have the correct settings, in order to communicate (not always easy). I have had the same problem with another converter as well. And like "RLGAUTO" I have had one that does...
  10. hillimonster

    RS232 smart cable

    Man that guy is GOOD, one cable!!! Thats what kills me about the movie Independence Day where the Computer Guy is able to download a virus into an alien computer in 5 seconds (no mention of interfacing problems). Sometimes I spend 1/2 day getting one Allen-Bradley component trying to talk to...
  11. hillimonster

    micrologix 1000

    why don't you compare the rate of parts going in to the rate of the parts going out? If the ingoing rate is 1 part per second, the outgoing rate should get to one part per second (after an initial transit time). If the rate out goes down to 1/2 part per second, then one is missing. I don't think...
  12. hillimonster

    1771 AB I/O module in a remote rack, need help changing the scaling

    Are you trying to change the scaling of a point, meaning 0-10VDC to 4-20mA. Or are you trying to rescale a particular channel so that it reads correctly. I can give you the register locations for the later (based upon PLC5 documentation) and probably for the former as well (just have to look in...
  13. hillimonster

    What is toc time?

    TOC I believe is "Theory Of Constraints' http://www.rogo.com/cac/FAQ.html http://www.rogo.com/cac/whatisTOC.html This is a Six Sigma / Lean Manufacturing term for getting the job done.
  14. hillimonster

    Control System home project

    Home Automation Basics by Thomas Leonik at Amazon
  15. hillimonster

    UPS needed for PLC

    We usually use off the shelf commercial units, they are much cheaper than any so called industrial units. Most UPS's are use for commercial computer backup. We strap them to the bottom of the electrical cabinet with a bracket. We have also used inexpensive velcro for a hold down, but it doesn't...
  16. hillimonster

    Reject Paint Marking System

    The carco markers (from what I have used) could be called spitters or spritzers. The cheaper ones tend to be messy over time, but because of the ink mess (drips) they don't clog as much. One thing that we have used for simple dots is an off the shelf marker attached to a cylinder 'head'. When...
  17. hillimonster

    Allen Bradley 1784-T30 Terminals

    We used T-30's for quite some time and we also replaced them with a Xycom product (I don't have the part number off hand). Xycom made the terminal for AB, or there were only minor variations. In order to communicate to it you need to use an XT keyboard (these are not easy to find these days)...
  18. hillimonster

    HMI Application using VB6.0

    One additional avenue that I have done for slower comm rates is rs-232 to visual basic MSCOMM. This works well on Allen-Bradley Micrologix to Computer. The resource that I used to get started was "Home Automation Basics" by Thomas Leonik, which was obtained from Amazon. For me (PLC background)...
  19. hillimonster

    Volume of GAS

    Sorry for lack of specifics. 50% mix of air and helium. An evacuated tank with 50psia of air added initially and then 50psia of helium added. Or this could be at 50% mix using a gas analyzer. The additional 100% helium is added to 200psia. All pressure indications using a psia pressure...
  20. hillimonster

    Volume of GAS

    This may be a simple question, but for me I'm not sure what formula(s) to follow. If I have a 30 Gal tank with a 50% mix of helium and air at 100 psi and I add 100% helium up to 200 psi. What is the volume of helium I have added. I'm a controls engineer by trade and if I add a feature like...