Search results for query: *

  1. snox135

    Excel data collection dropout with Rslinx

    What are you using for a data collection program?
  2. snox135

    Can Panelbuilder read UDT's?

    Yes, the standard PanelView will read the standard UDT's fine.
  3. snox135

    rslinx opc excel

    You sould be able to access the spreadsheet over your network on any PC without changing anything. As long as the RSLinx PC is on the same network. We do this with our InSql data, which should be any different than getting the data directly from the PLC.
  4. snox135

    CSV in RSLogix 5

    Open the file that contains the database, clic save as and check the Save database as a external file box. Then, open the program you want to import database and clic tool --> database --> native import, clic ok. That should be what you are looking for. I don't think RSLgx-5 handles them in a...
  5. snox135

    Synchronous vs Induction on a centrifugal compressor

    Wouldn't removing the 1:2 speed increaser decrease the load on the motor? If this is the case couldn't he use a smaller hp motor? Thus increasing his savings.
  6. snox135

    Can Panelbuilder read UDT's?

    The panelview should have no problems using the UDT's. I know we do use some like this. But I don't work with the panelviews very much and I was not aware of a PV+RSView. I will look into the PV's that we have and check this out for you.
  7. snox135

    rs linx

    You can view code from RSLinx but I would not suggest doing so. When searching for a address you must search each file seperatly. It does not search the hole program buy it self. Like EddieWillers said you can only browse it will not allow you to make any edits.
  8. snox135

    Would this be a difficult PLC application?

    We actually have an application vey close to this, except on a larger scale. One thing you might want to look into is instaed of 3 sensors switch to one analog sensor. Then you can use it's value to turn things on and off as you wish. Then you could also display the actual level on your screen...
  9. snox135

    Megger testing procedure for 9 lead wye motor

    No, No there was no misunderstanding. You gave him the exact info I was looking for. I already knew the continuity and to ground. I just wasn't sure of the windings to windings test. Again thank you.
  10. snox135

    Megger testing procedure for 9 lead wye motor

    Thanks for the information. I was looking for the windings to windings connections. Thanks again for the help.
  11. snox135

    Megger testing procedure for 9 lead wye motor

    I was hoping someone would know where I could find the proper testing procedure (megohmmeter phase to phase)for a dual voltage 9 lead wye connected motor? I found one for 9 lead delta at aemc.com but I cann't find one for wye connected. Any help would be greatly appreciated