Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. slickdeals

    Issue with centre of rigidity in ETABS

    Are all diaphragms defined "rigid"? ETABS will report it only for rigid diaphragms.
  2. slickdeals

    Reaction Values Displayed Despite No Restraints ETABS

    Can you make sure your analysis doesn't have YZ plane restrained in the "active degrees of freedom"?
  3. slickdeals

    Development length schedules

    Cliff - the public comment ACI 318-25 had the hook development lengths returning to ACI 318-14 or close to it. In addition, like Celt83 mentioned, a lot of the crazy seismic amplification is getting scaled back. It will still be worse than before, but much better than 318-19. Hopefully they'll...
  4. slickdeals

    Development length schedules

    How do your firms show development length and lap splice schedules on construction drawings? Do you have the most conservative value calculated prior to the modifiers applied and spell out how the modifiers apply? For example, a #5 bar in 5000 psi concrete has a hook development length of 15"...
  5. slickdeals

    Drilled peir shear check and ties requirements

    You would consider it as a column and design as such. Yes, one tie contributes to two legs. Similar to a circular column. You would use effective depth as 0.8 times diameter. You can review ACI 336.3R or ACI 543R-12.
  6. slickdeals

    How to reference "generally accepted engineering standards"

    It looks like he has multiple restricted endorsements. Don't know what the basis for the board granting those are. https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=593501B6C755C3C26BCCC7D0CC079ADD
  7. slickdeals

    How to reference "generally accepted engineering standards"

    What was an electrical engineer doing review of windows?
  8. slickdeals

    How to add longitudinal torsional reinforcement to longitudinal flexural reinforcement in beams?

    You calculate your top and bottom reinforcement, then calculate your additional longitudinal rebar for torsion. For example, you needed 8 in2 for torsion, you would divide it equally on 4 sides (or proportion based on beam depth width ratios). If you had 4#9 top and bottom already, one way to do...
  9. slickdeals

    ACI318 for Anchor to Masonry Design?

    I recently looked into this and they're using AC58.
  10. slickdeals

    STM - Wall on wall detail

    Haven't read all of this, but be careful using the increase for sqrt (A1/A2) as you don't have confinement in both directions.
  11. slickdeals

    Wind drift - Can drift due to gravity loads be subtracted?

    @EngrRC - for buildings where gravity loading isn't symmetric, it is not unusual to end up with lateral movements resulting from it. When such types of buildings exist, you should consider running construction sequence analysis. ETABS (and other programs) have the ability to analyze the building...
  12. slickdeals

    Gravity columns design in high seismic region

    In order to calculate the induced moments and shears due to design displacement, you can create a load combination that amplifies the moment by "Cd" factor. The inelastic (design) displacement is the seismic displacement amplified by Cd factor. I don't believe you need two separate models...
  13. slickdeals

    Concrete beam loaded at the bottom?

    If your D2L anchor is developed to resist the tension in the member, then I don't see an issue. This would be no different than rebar being developed in a tension member (net uplift) anchored to a footing. I agree with TLHS that it is best to be conservative with the development length and use a...
  14. slickdeals

    Concrete Column Transitions - Bearing Area

    I have in the past taken "fanning out" to middle of slab thickness. So I would go 200 x (200 + slab thickness) on each column.
  15. slickdeals

    Gross vs Net Allowable Soil Bearing Pressure

    If it was net bearing pressure, the answer would be f. Only consider the column reaction.
  16. slickdeals

    Gross vs Net Allowable Soil Bearing Pressure

    I would first ask the geotechnical engineer to clarify net vs gross. When it comes to net bearing pressures, typical practice is to ignore the weight of the soil and footing and only consider the applied loads to it.
  17. slickdeals

    Punching Shear Interaction with 2 Columns

    Treat each of these columns independently for the axial loads and moments they carry. It looks like you are transferring a column on to a slab.
  18. slickdeals

    Earthquake Load Patterns in ETABS

    You don't need to have six different load cases. You have the ability to override diaphragm eccentricities for each level. The value of eccentricity is input as a value in feet, which is based on the actual eccentricity.
  19. slickdeals

    Textbook recommendations

    There's mention of backstay effect in NERHP Tech Briefs on Diaphragms, and also in the LATBSDC document. It is a real phenomenon that needs to be considered.
  20. slickdeals

    Outrigger beam modelling as shell or frame in ETABS

    A rigid diaphragm means zero in-plane displacement, as it is infinitely rigid. So if the two ends of a beam are rigidly connected (constrained), there will be no movement relative to each end and hence, no axial force.