Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Milutin

    Slop processing on Visbreaker Unit

    Dear all, We want to start processing refinery slop oil on Visbreaker oil. Slop properties are similar to light crude oil, but can contain up to 5-10% water. My question is how and where to connect slop line to visbreaker unit. Regards, Milutin
  2. Milutin

    Flare capacity problem

    Hi Emmanuel, For FCCU main fractionator loss of electricity going to cause loss overhead cooling and for sure relief to flare, is it acceptable to backup power source with diesel generator to prevent loss of cooling? For ADU unit it is same scenario for power loss, and you are right excessive...
  3. Milutin

    Flare capacity problem

    Sorry, what abbreviation IPF mean?
  4. Milutin

    Flare capacity problem

    Dear all, In our refinery we have some PSV designed to discharge to atmosphere, most of them are on top of ADU, FCCU and visbreaking main fractionators. Because we consider that as safety and environmental issue we want to connect them to flare. This is problem because when we calculated...
  5. Milutin

    C6+ in Recycle Gas

    Hi, what happens with outlet tempetature from Cold High Pressure Separator, did it increased from some reasons? This can increase heavy HC content in recycle gas. Regards,
  6. Milutin

    SR naphtha reforming

    We tried hydrogen stripping but with no effect. I am attached several diagrams for better understanding. http://files.engineering.com/getfile.aspx?folder=5a221fc3-4570-40e9-81a5-66b1d4c23706&file=R-Delta_T.png...
  7. Milutin

    SR naphtha reforming

    Yes, according to content in recycle gas, chlorides are ok, but anyway we increased dosing rate from 0,6 to 2 ppm, but no response from reactors. At thist stage there are no response on octane nuber even if we increase reactor temperatures it seems to me that catalist is complitely deactivated...
  8. Milutin

    SR naphtha reforming

    We don’t do water and chloride content in reformer feed as regular analysis. I have two recent values for water in reformer feed 7 and 12 ppmw. Method is by coulometry. We also inject 5 ppmw of methanol for water control.
  9. Milutin

    SR naphtha reforming

    25362, As wrote previously,after first emergency shut down recycle gas H2 content and reformate yield started to decline,after evry next SD this trend accelerated, yes in may opinion this is problem from beginning of cycle. Nitrogen content in hydrotreated feed is very low about 0.1ppm, in...
  10. Milutin

    SR naphtha reforming

    Yes, sulfur can deactivate reformer catalyst, this value 0.5ppm is design value for sulfur level. Sulfur is also easily detected by increased H2S concentration in recycle gas, this value is normal.
  11. Milutin

    SR naphtha reforming

    Hi all, Is it possible describe clear symptoms for following reformer problems: - metal poisoning - overchlorinated catalyst - underchlorinated catalyst - catalyst end of life - problems caused by poor regeneration Our reformer has following deviations from normal operations: - low dT on...
  12. Milutin

    Light naphta mixed with Medium gasoil?

    Hi, Flash point can be problem, do you have specification for it? Take samples of light naphtha and gas oil mix it in desired proportion and take it to lab, if all spec. are ok you can use it. Milutin
  13. Milutin

    VDU ejector off gas

    Thank you for your replay dcasto. Stream description is: Pressure:0.05bara Temperature:50degC Quantity:1000kg/hr Composition: H2S 30 mol% O2 0.1mol% N2 1.7mol% CO 4.4mol% CO2 0.4mol% H2 2.4mol% Rest is light hydrocarbons. Suppose it is necessary to increase stream pressure and send it amine...
  14. Milutin

    VDU ejector off gas

    Off gas from the refinery vacuum distillation unit is routed to fired heater. Off gas is rich in H2S and results with increased SO2 emmision from VDU heater. What are the cost effective solution available to remove H2S from this stream? Regards,
  15. Milutin

    Refinery own consumption and loss

    What is best performers (and not so best performers) own consumption and loss for an modern oil refinery in Europe region? Regards, Milutin
  16. Milutin

    crude oil approval process

    Hi dieselpet07 In my opinion it is necessary to consider impact of new crude oil on refinery economic and process plants. To see economic impact you can use LP software like PIMS, this can tell you how much refinery profit is increased or decreased when new crude oil is processed, crude oil...
  17. Milutin

    calculation for smoke point for kerosene!

    It is not possible to get this book for free, it is copyrighted. Regards, Milutin
  18. Milutin

    calculation for smoke point for kerosene!

    Hi checkon, You can find calculation procedure at API Technical Data Book, Chapter 2 - Characterization of hydrocarbons. I am not sure if commercial simulators has ability to calculate smoke point. Regards, Milutin
  19. Milutin

    Carbon Disulfide in Naphtha

    Hi dieselpet07, Does CS2 in light naphtha cause any problems in process or equipment downstream of naphtha splitter or what is reason for your concern about CS2? To investigate source of CS2, crude oil or process, you can tray to distillate crude oil in simple and inexpensive ASTM D-86...
  20. Milutin

    Increased nitrogen content

    Dear Mr. JJPellin, Thank you for shearing your experience with us. Nitrogen in reformer feed going to convert to ammonia, and react with chlorides to form ammonium chloride. Reforming is "dry" process and no liquid water exist to wash ammonia chloride deposited salts. Salts will usually...