  1. ducking

    Inductance in a Three Phase Transformer Model

    Can somebody help me? this is my problem, I'm modelling a three phase transformer and getting the L(inductance) matrix. I know than L=Ll+Lm where Ll= leakage inductance and Lm= inductance of magnetization I also know that Lm1=(n1/n2)*L12, and Lm2=(n2/n1)*L12 where L12= mutual inductance...
  2. ducking

    Stores as a parameter - batch mode

    Hi jvst Try using the comando *get regards ducking
  3. ducking

    current flow

    OK Best regards Lucky
  4. ducking

    current flow

    Could you be more specific, what are you modeling?, I think you mean, the Total current flowing in the source
  5. ducking

    conect node of element CIRCU124 with SOLID231

    Hi Jorand first you have to coupling nodes in some area that you want then you have to choose a node (inside) and apply the voltage, obviouly, in order to have a voltage in the block in other area of this block you have to apply a 0 voltage I hope you can undestand my bad english Lucky
  6. ducking

    electromagnetic circuit simulation SOLID117

    Hi michael I don't understand this part in your question "I try to simulate an iron region which is magnetised by a solid massive conductor (SOLID117 Keyopt(1)=5)" What are you trying to do with this? other thing, how your current source for the conductor is? as you know the error...
  7. ducking

    Join and support

    Hi Javier The glue operation redefines the input volumes so that they share areas along their common boundaries. The new volumes encompass the same geometry as the original volumes Adds Volumes =Adds separate volumes to create a single volume. The original volumes (and their corresponding...
  8. ducking

    [b]leakage inductance in a Three Phase Transformer (Ansys)[/b]

    Hello I'm modeling a Three Phase Transformer in 3D using ansys and I have a problem I want to get the Leakage Inductance, but I don't know how to do it, I'm using the LMATRIX to get the L matrix and Etype=SOLID117 I would greatly appreciate your suggestions and help. Regards...
  9. ducking

    SYSTEM UNITS

    Hi cbrn, I have to admit that you are correct, I just can say from your exaples, as you said, "It's the user which must ensure he inputs the values in a consistent system" Regards Lucky
  10. ducking

    SYSTEM UNITS

    ANSYS uses for defect the MKS system (always), therefore, your 10 will become 10 meters, For example in electromagnetics (my area)if you want to change this system use: Preprocessor>MAterial Props>Electromag Units Lucky ducking79@hotmail.com
  11. ducking

    3D FEA recommendation?

    I use FLUX3D and Ansys both are highly recommended but flux3d is cheaper than Ansys Lucky