Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. WaterMan22

    Ultrasonic flowmeter

    Accusonic and Rittmeyer are also good companies.
  2. WaterMan22

    Square vs. Round Wire Torsion Spring

    Can anyone tell me if there is a benefit to using square wire, as opposed to round wire, for a large torsion spring? I need to replace some damaged springs (square wire), but can't locate a manufacturer who can build them. I am told that a round wire type can be readily produced. I...
  3. WaterMan22

    Draft Tube Maintenance Platform - Vertical Hydro-Turbine

    These turbines were installed in the early 1960's. The original contract specification didn't have any wording for a maintenance platform. Given their age there is need to perform inspections and repairs from below the runner. I just want to know what procedures or guidelines other...
  4. WaterMan22

    Draft Tube Maintenance Platform - Vertical Hydro-Turbine

    Is anyone aware of a procedure and/or design for installing maintenance platforms in the draft tubes of vertical hydro-turbines? In one of our facilities we "float the boat". Which entails raising the water in the draft tube to just below the man-door and a maintenance person on a makeshift...
  5. WaterMan22

    Evaluating Aging Penstocks

    The USBR has a manual (FIST 2-8) on penstock inspection that may answer your question. Also, I believe ASCE has a book written on the subject (Guidelines for Evaluating Aging Penstocks). http://www.usbr.gov/power/data/fist/fist2_8/vol2-8.pdf
  6. WaterMan22

    Vibration limits for GE turbine generator

    ISO 7919 is a good source for understanding/setting vibration limits as it covers a wide array of machinery types. Depending on your machine there are 5 parts (1-General guidelines; 2-Large Steam Turbines; 3-Coupled Machines; 4-Gas Turbine Sets; 5-Hydro Turbines)
  7. WaterMan22

    Kaplan Hydro Turbine

    No, the unit should rotate in the normal direction. Although, it may run a bit rough.
  8. WaterMan22

    Surface Finish Callout

    I would check with the customer for clarification. They may be trying to designate: 0.2um and 8u-in, which are synonymous on the Ra scale.
Back