  1. gmazumder

    CORE BALANCE READINGS OF A TRANSFORMER

    Is the transformer a new one or an old one, has the transformer been shifetd from some location to this location and how do the results compare with the factory tests results. What all tests have been conducted on this transformer and what is the sequence of the tests carried out. The...
  2. gmazumder

    230 kV XLPE UG Cable in Steel Encase Pipe

    you may not br sble to run for such a long length in a trefoil condition as suggested by RajT. It is not suitable to run single core cables in metallic ducts and specifically if you cannot maintain the trefoil condition. hope this helps
  3. gmazumder

    Shipping of oil filled equipment

    Wowski, Its a standard practice to ship tarnsformers and reactors in dry condition. The reactor oil is best drained under the pressure on Nitrogen gas and that minimises the exposure of the insulation paper to the atmospheric conditions. The trnasformer is to be held under slight pressure to...
  4. gmazumder

    Congrats to electricpete

    congrats, electricpete
  5. gmazumder

    Distribution Transformer Specs.

    Distribution Transformer: Conventional Distribution Transformer (500kVA - 2000kVA) Product Specification Table For Distribution Transformer Enquiry Form Type Copper wound distribution transformers are manufactured in accordance with IS 2026-1977, 3 phase, 50Hz. Oil Natural Air(ONAN)...
  6. gmazumder

    AMORPHOUS CORE TRANSFORMER

    Dear SphincterBoy, I can give you the correct address and contact person of the manufacturer in india as i am associated with them.
  7. gmazumder

    Transformer Winding Costruction

    it seems that i will have to contradict you all in the above mentioned posts. The sheet winding is known to be more solid in formation and as the fault current gets distributed over the sheet per unit force is lower compared to the stranded conductor winding construction. Generally the failures...
  8. gmazumder

    Transformer Dissolved Gas Problem ??

    single test results increase is many a times misleading and as suggested by other members trending and comparision of the ratios is the correct analysis methods. recently about an year back the ratios have been modified by the CIGRE group 15 and the new ratios are more accurate in their...
  9. gmazumder

    Transformer Sheet Windings

    i think what you are talking about is also referred to as the Al foil transformers. These transformers are known to have high fault withstand capacity and are good performers. you have provided lot of details in the thread and the replies and i need to know more details. the high voltage...
  10. gmazumder

    Do you purge the air from draw lead bushings?

    Dear Stevenal, you have not given two data, the voltage class of the bushing and the transformer has a conservator or not. As far as i am aware it is not necessary to purge from the bushings if the tank has a n2 based oil preservation system as the N2 is over the oil, but there are instances...
  11. gmazumder

    On Line Transformer Oil reclamation and overhauling

    Dear soorya, one of the other eqiuipment manufacturers is enervac and you can find some details at www.enervac.com and not enercon as mentioned by me earlier. if possible send me the oil test reports ans i can be of help. my email id is gmazumder@yahoo.com regards
  12. gmazumder

    On Line Transformer Oil reclamation and overhauling

    dear soorya, i think now the technology of online filtration is quiet well established and the activity can be undertaken. the inlet to the filter machine is taken from the bottom of the transformer and the recycled oil is fed to the top of the transformer or to the conservator. sludges do...
  13. gmazumder

    On line oil filter

    i think you are talking about bushings interfacing SF6 switcggera to the transformer, the bushing is most probably oil to sf6 type or is it of some other type. for oil to air type the online oil filtration system can also be used, as it only keeps the oil in good condition and minimises oil...
  14. gmazumder

    Substation Transformer Windings

    i am talking of distribution transformers up to 3-4 MVA range, for 10 MVA range the size and design complexity may increase and the cooling will also have to be carefully looked into.
  15. gmazumder

    Substation Transformer Windings

    rectangular coil transformers have been in use for quiet some time. the rectangular coil is actually the Lv winding and the same is made out of foils either copper or aluninium. generally the HV will be conducter type and the core is rectangular in nature. the core is held in position by s frame...
  16. gmazumder

    POWER TRANSFORMER DESIGN

    definetely possible, a two winding transformer can be designed for your use. Why dont you give some more details of the transformer required by you. also we need some information of the generator and are the impedance levels of both the transformers same.
  17. gmazumder

    Student requires assistance of degree qualified engineer

    you can also send me the questions that you want to be answered.
  18. gmazumder

    One 240mm¦ or 2x120mm¦ solution ?

    your choise is correct and the handling has to be done once while installation only. You need to keep the usual precautions in mind and you are well aware of them.<br><br>My considerations would be<br>1.Maintenance cost.<br>2.Down time cost.<br><br>other parameters are equally important but as...
  19. gmazumder

    Relevant information about termovision

    there are two web sites<br>flir.com<br>landinfrared i am not sure about the name of this one<br><br>if you get any thing regarding diagnostics please also intimate me at <A HREF="mailto:gmazumder@yahoo.com">gmazumder@yahoo.com</A><br><br>regards <br><br>gautam mazumder<br><br>
  20. gmazumder

    Hydro Turbine

    can you send me some photographs at <A HREF="mailto:gmazumder@yahoo.com">gmazumder@yahoo.com</A> then i will be in a position to comment and the remedial process to be followed for the same.<br><br>regards