Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Baires92

    Catenary Cable Tension

    OK, now we have: Assumed: Cable: 7/16 inch EHS 7 Strands Steel, Section 0.1156 in^2, Weight 0.399 lb/ft Initial condition (loads added): Load 1k each 1/3 of the span Span 1100ft, sag 21 ft Tensions: Horizontal 20294.5 lbs, Span Max 20331.0 lbs (98% of the ultimate tension capacity, NG for...
  2. Baires92

    Catenary Cable Tension

    The resultats of the FE analysis with PLS-CADD software: Assumed: Cable: 7/16 inch EHS 7 Strands Steel, Section 0.1156 in^2, Weight 0.399 lb/ft Temperature initial and final 60F Initial condition: Span 1100ft, sag 21 ft Tensions: Horizontal 2872.2 lbs, Span Max 2880.5 lbs Final condition...
  3. Baires92

    Building codes in Russia

    Fortunately, I've found english version of SNiP Do you need russian speaking person for your projects in Russia? ;)
  4. Baires92

    Building codes in Russia

    Une petite cadeau pour toi, my friend.http://files.engineering.com/getfile.aspx?folder=fd4564aa-869f-44e0-b50d-a2050c596db7&file=SNiP_2.01.07-85.pdf
  5. Baires92

    Reinforcement rebars recognition

    I need to check the design of the communication tower on the existing building. One of the legs of the tower rests on a reinforced concrete beam which design is not available. My question is – up to date exist, and if so, what methods of nondestructive detection of the position and # of the...
  6. Baires92

    Canadian Steel 350W

    Voici la table avec les caractéristiques de l'acier CAN/CSA-G40.21 Grade 350W Bon chance, chérie Best regards from Montreal http://files.engineering.com/getfile.aspx?folder=c97db5e8-0b3b-4a40-83c7-abe38541f2b3&file=CSA_G40.21.pdf
Back