Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  • Users: HPMach
  • Order by date
  1. HPMach

    centrifugal compressor efficiency

    Efficiency is not an independt term and defintiely it will be linked with equipment (with in the reasonable band). If the operating parameters established appropriate, it is possible to reach around 80-85% on centrifugal machines. I am not sure why you are saying 4stages in your case. Each stage...
  2. HPMach

    HAVE YOU EVER HEARD OF SOMEONE DOING THIS?

    Recently there is a safety issue raised by IR on VIP units. VIP units are there in market for almost 10years.
  3. HPMach

    Gas Compression: Engine Driver vs Electric Motor

    5000HP Motor most likely needs to Synchronus motor for recip application, though speed is in the order of 900rpm. Adding such a big motor would definitely push you starting current issues unless you add significant additional generation capacity. As discussed in several responses above, unless...
  4. HPMach

    Pump Suction Screen size

    If it is permanant strainer, I think for Centrifugal pumps 40Mesh is the size vendors recommed. Normally for stabilised streams in refineries permanant stariner is not needed, as no sloids are expected, unless it is from crude oils torage tank/transfer pump service.
  5. HPMach

    Hydraulic vs. electrically driven pumps?

    Original selection of drive will primarily depends on availability of power source & suitability. I would say Hydraulic system is complicated, if it is for continuos duty and controls are required.
  6. HPMach

    Solids Handling Capacity

    Agree with the point that it is to be designed specially, unless the solids referred are fe micron levels. Still end up in damaging the seal
Back