    DC Motor Starter - Resistor Sizing

    Scotty Worked a treat. Thanks for your help. H
  2. eti

    DC Motor Starter - Resistor Sizing

    Scotty Thanks Weve got the original data sheet for the motor so know quite a bit about it. Its got 2 field windnigs so it could be shunt or compound. I think we will go with timer start. Do I calculate resistor sizes according to the starting current limit I want to achieve at each of the 3...
  3. eti

    DC Motor Starter - Resistor Sizing

    Scotty Thanks for this. Ive got the original motor data sheet, so armature and field resistances. There are 3 stages, the fourth contactor is the last (but first to close) that acts with the overload to protect the motor should that be required. Are the calcs straightforward then? Cheers H
  4. eti

    DC Motor Starter - Resistor Sizing

    Hi Everyone I've got an old DC motor starter to refurbish (2HP). Photo attached. I'm not sure about the starting arrangement, back emf or timer. Any clues? Once I've worked out the starting arrangement I need to size the resistors. Again, any clues? Cheers H
  5. eti

    GEC CDG 34 Electromechanical Relay

    Dear all Thank you for the advice. Scotty, there is a CDG14 protecting the same feeder for earth fault, so the CDG34 is probably only doing overcurrent. I've confirmed it's a 5A relay, so a fairly high burden. The sverker unit we have will probably be ok, it can deliver up to 50 single phase...
  6. eti

    GEC CDG 34 Electromechanical Relay

    JG, I need three phase. Not sure what current, I'll have details of the CT's etc tomorrow.
  7. eti

    GEC CDG 34 Electromechanical Relay

    Hi I have a one off GEC CDG 34 relay to test, a legacy relay left on a fairly new system, it protects an 11kV transformer feeder. The remainder of the relays are modern digital type. Can anyone suggest a suitable secondary test set for the high currents involevd?
  8. eti

    the magnetising current

    Guys I'm running up a new dry cast transformer tomorrow. No load on it yet but it will feed some 11kV pumps in the coming weeks. I'm connecitng a Ranger 7000T power quality analyser to get a feel for it's effect on the system, including harmonics. I'll post the results tomorrow evening (GMT)...
  9. eti

    ETAP Users - Ideal Generator

    Hi. I'm studying a power system which has a 3.3kV 2500kW Ideal Electric Generator, Frame 21120. I can't get a hold of the information for the impedance model, dynamic model and Q,a,b,c, PMin figures. Has anyone modelled this one before? Cheers eti
  10. eti

    Which Digital Relay?

    Ah Scotty That all depends on what side your on?? I'm north, but only just. Support for GE is a bit of a concern but I've seen their guys quite a bit lately on another project. Not directly employed but part of a good network. Your spot on about testing. Lots of kit today tests the software...
  11. eti

    Which Digital Relay?

    Hi All. Thanks for your advice, all very useful. It's come down to GE, Siemens and Areva. Integrating the GE relays look like the easiest job to engineer (Yes LOADXFER I'm doing that all by ma wee self and I do know how to engineer it. I fact, I might even fit them myself just for the fun of...
  12. eti

    Which Digital Relay?

    lz5pl Thanks, very useful. I also like Siemens and Areva and both provide good support. I'll look at the VAMP agan. I've got some experiecne with them and is was all good. Proven units are the way forward. Cheers eti
  13. eti

    Which Digital Relay?

    Dear all. Thank you for your contribution. To answer a frew point; The installation is heavy industrial and in the UK. It's mostly protecting 11kV, mainly transformer feeders, but some motors. We do not require to derive any signal other than basic local alarms. No SCADA for example. My...
  14. eti

    Which Digital Relay?

    Hi all I have a large number of old GEC relays to replace and have been looking at the digital relays on offer. I can't see much between them in terms of function. I got a long list down to GE Multilin, Schneider SEPAM, Areva MIDOS and Siemens SIPTOTEC. Does anyone have experiecne of how...
  15. eti

    GEC CTZ 71 Protection Relay & 800A IM-PACT ACB

    Scotty I haven't tried St. Leonards Works. I'll give them a call tomorrow. Thanks ETI
  16. eti

    GEC CTZ 71 Protection Relay & 800A IM-PACT ACB

    Does anyone have a copy of the manuals for any of the above legacy GEC units? I've already tried Areva? Thanks eti
  17. eti

    Trifid T2030P Power Analyser

    Scotty. Thanks, I had considered it. I opted for the middle ground and contacted Cuthbertson and Laird (I purchased from them about 8 years ago). They kindly made a copy of the disc they send out with their hire instrument. Problem solved.
  18. eti

    Trifid T2030P Power Analyser

    That would be my first port of call, but I think they have been taken over by another company. There is no longer any reference to it on the web. The search continues.
  19. eti

    Trifid T2030P Power Analyser

    Does anyone know where I can get a hold of the software for a Trifid T2030P Power Analyser (datta logger). I've had the instrument for year but lost the laptop drive the software was installed on.