  1. AIOR

    ASME versus A97075

    The starting point for a material selection would be a construction code such as ASME Section VIII Div. 1. Your material UNS A97075 is not listed in Div. 1, and also not listed in Div. 2. You can not use this material in Code pressure vessels. You can build small pressure vessel as a non-code...
  2. AIOR

    PWHT

    I assume that you are dealing with a UCS material, no process PWHT necessary. Here are some Code statements: UCS-56 (a): PWHT is required when the nominal thickness, as defined in UW-40(f), exceeds the limits in Table UCS-56. (This means that not all welds require PWHT). UW-40 (a) (5)...
  3. AIOR

    Russian GOST Requirements

    The name of Russian PV Code is: ?? 03-576-03 ??????? ?????????? ? ?????????? ???????????? ???????, ?????????? ??? ????????? (Rules of Construction and Safe Operation of Pressure Vessels). This Code was revised in 2003. You can follow this link to see the document in Russian...
  4. AIOR

    Dose the ASME U Stamp status changes

    Hi, Your question is of a jurisdictional matter pretty much. After the vessel was finally completed and final ASME stamp was applied, ASME rules will be no longer applicable. From this point, any welding to pressure retaining elements will be regulated by a local Jurisdiction. If adopted by...
  5. AIOR

    Tube Sheet Crack

    Hi, steamer1966, I understand, this is a repair that shall be done by R-Stamp holder in accordance with NBIC. After 20 years of service there may a lot of invisible micro-cracks that may initiate a crack propagation after welding. Therefore, the first step should be a thorough examination using...
  6. AIOR

    r stamp requirements

    In addition, you can find a sample Manual at: http://www.authorizedinspector.com/Training_Materials/Training_Materials.htm. Good luck
  7. AIOR

    R Stamp UM Vessel

    Hi, An UM stamped vessel without a NB number was still built per ASME Code and can be repaired per NBIC including a Code Stamping. Moreover, NBIC is applicable not only to an ASME stamped items but to any pressure retaining item, does not matter, it was registered with the National Board or...
  8. AIOR

    Pressure Test Guages

    Hi, Shariku ot Bobika. This is not a “Newton Binomial problem”. Per UG-102 (b) a rule about a gage range “not less than 1.5 not more than 4 times the test pressure” is only applicable to a dial pressure gages. For digital pressure gages a wider range is allowed. Thanks
  9. AIOR

    PWHT Sect. VIII Div. I

    Hi, It looks like the only option available is a local PWHT for your attachment welds per UW-40. Thanks.
  10. AIOR

    ASME IV versus ASME VIII Div 1

    Hi, The standard domestic (potable) hot water storage tanks are usually built per ASME Section IV with HLW Code Stamp. Max design temperature is 210 F and MAWP 150 psi. Such tanks usually have anticorrosive lining inside. Thanks,
  11. AIOR

    ASME-Authorized Inspector

    Answer: the National Board. Each candidate for AI first becomes a NB Commissioned Inspector, see a link: http://www.nationalboard.org/Index.aspx?pageID=6&ID=28 Then he takes A-Endorsement exam at NB and becomes an AI. Each AI is annually issued a Commissioned Inspector card with at least...
  12. AIOR

    Is it a pipe or is it a vessel?

    Per Sect VIII-1 Scope (U-1(a)(2): pressure vessels are containers for the containment of pressure...Also, per U-1(c)(2)(e) piping components are exempt.
  13. AIOR

    Repair work

    Per 2007 Edition of the NBIC, Para. 4.4.2, for an alteration test you may use a) Liquid Pressure Test; b) Pneumatic Test; c) Nondestructive Examination. NDE may be conducted when contamination of the pressure-retaining item by liquids is possible of when pressure testing is not practicable...
  14. AIOR

    ASME Sect. VIII - Flange Calcs

    Using 300# standard flange is definitely a better practice. Your non-standard flange will cause changes in the drawings and calculations. It may not in compliance with the customer specification and will need customer approval. This issue needs to be addressed in the Manufacturer's Data Report...
  15. AIOR

    RT Before or After PWHT

    As said above by weldtek , RT shall be done after PWHT for high alloy steels per UHA-33. This is because a delayed cracking or post heat treatment cracking may happened in or adjacent to welds after PWHT. This is not applicable to UCS steels. Common sense: you always need to do RT before PWHT...
  16. AIOR

    ASME Section VIII and re-rating a vessel's MAWP

    Because this is a post-fabrication issue, ASME Code may be used only as a construction standard to support an in-service repair/alteration code accepted by a local jurisdiction, like NBIC in USA. Per NBIC, re-rating is a part of alteration and can be done by a R-Stamp holder in compliance with...