Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Lutfi
  • Order by date
  1. Lutfi

    Combined Timber and Microlam Beam Load Sharing

    You are correct. The plan to consider loading the LVL for the live and wind loads only. It s to risky, I think, to jack the beam and alleviate the dead load.
  2. Lutfi

    Combined Timber and Microlam Beam Load Sharing

    Thanks for the response. Your thinking and approach lines up 100% with mine. Cheers!
  3. Lutfi

    Combined Timber and Microlam Beam Load Sharing

    It has been a long while since I have been in this forum. Hello everyone. I want to pick everyone’s brain here. I have been called, of course after the fact, to evaluate a situation where a contractor has already installed a beam, 9.33’ span made up from SYP number 2. The beam is supporting 5...
  4. Lutfi

    contractor not following plans... at all

    If what you are saying is 100% correct, then run Forest, run away from this job, as fast as you can.
  5. Lutfi

    Digitally sign Structural drawing

    My current certificate will expire in few months and they are raising their fees. For cost comparison, before I renew, would you tell me which one they pointed you to? Their website and selections do not have FL board of engineers.
  6. Lutfi

    Digitally sign Structural drawing

    I have been using Entrust. Her is a link to their web site: https://www.entrust.com/
  7. Lutfi

    Florida Threshold Inspections

    Follow the threshold inspection plan that must be generated by SEOR.
  8. Lutfi

    Fall Protection on Platform

    OSHA and now ASCE 7 part 4.6.5 has provisions as the fall protection forces. ASCE 7 requires 3100 pounds live load. Keep in mind, if I recall correctly, when designing for these forces, you can use the ultimate strength.
  9. Lutfi

    Digitally sign Structural drawing

    That is right. Florida has strict procedures, as it should be.
  10. Lutfi

    Digitally sign Structural drawing

    Are you serious? What state is that?
  11. Lutfi

    Digitally sign Structural drawing

    Florida has strict procedures for digital signing and sealing. We cannot rely on simply using digital signature in Acrobat or Bluebeam. Hopefully the following link will help you: https://fbpe.org/legal/signing-and-sealing-engineering-documents/ Lutfi
  12. Lutfi

    Gross vs net uplift C & C Pressure

    I am curious as what fellow engineers here consider, to arrive at net C & C uplift pressure, as dead load resisting the gross C &C uplift pressure on roofs? Regards, Lutfi
  13. Lutfi

    Surcharge for a Sea Wall

    It is settled. A surcharge of 100 psf is what my engineering judgement is telling me. This is based on the project and what I know what will happen. Thanks for those who chimed in. Regards, Lutfi Regards, Lutfi
  14. Lutfi

    Surcharge for a Sea Wall

    TLHS, the site cannot be accessed by traffic due to existing trees, playground and fencing on two sides. The other tow sides are water/river. Lawn mower is the most that I can envision. I will use 100 psf. I was looking for a solid reference with surcharge values other than computing based on...
  15. Lutfi

    Surcharge for a Sea Wall

    All, I am analyzing a sea wall that is used for a small park. The wall is retaining 4 to 6 feet of earth with the water in the river side is about 3 feet above the mudline. The wall does not appear to be subject to vehicular traffic. I am of the opinion that 40 psf surcharge would suffice. This...
  16. Lutfi

    Crane Runway Beam Reinforcement

    Back in the day when I designed overhead cranes and runways, the channel was assumed to take the full lateral load. I wonder why the owner want the UC to be 0.85? Your approach seems to be viable. However, keep in mind that the DL from stiffening the runway add more more stress. bones206, I am...
  17. Lutfi

    Help W/ Risa Model

    I am late to this post but better late than never. That 1/2" plate, is it a canopy? Also, as a side note that has nothing to do with the RISA model, did you ever try to bend a 1/2" plate to create the lip at the end? I suggest that you consider changing the plate thickness unless driven by...
  18. Lutfi

    causes for cracking at embed plate

    Here are some of my comments: 1. The embed plate thickness is overkill for 600 lbs. 2. The number of headed studs at the end of the small cantilevered beam is not good. 3. RC beam reinforcement (top for tension and bottom to simply hold the beam ties in place) should have terminated with ACI...
  19. Lutfi

    CMU Blast wall design for HUD Construction

    Very specialized field. My advice is to hire an expert in this field. I have done a few of these designs in the past. The 0.5 psi seems low but it depends on the TNT equivalent weight and its locations form the structure. Dr. Sam Kiger with University of Missouri used to teach a week long class...
  20. Lutfi

    Water Lines under Heavily Loaded Footing

    It is a terrible idea to place a footing over any water or sewer lines especially if they are pressured. If the line ever breaks and the footing is undermined, the structure will be in deep troubles. My advice, based on over 40 years of experience, is to re-route the water line if you can...

Part and Inventory Search