  1. mikebuchter

    NX7.5 Sketch question

    The weird thing is, under Task -> Sketch Style... the "Fixed Text Height" is toggled ON, only when I uncheck it is when it the text stays at the same height.
  2. mikebuchter

    NX7.5 Sketch question

    I recently started at new company and some of the NX settings are different and I am having a problem trying to figure out the text size in the sketcher. I have the Fixed at Height box checked but when I zoom in and out the text is still getting larger and smaller, is there another setting...
  3. mikebuchter

    NX (x64) w/ Excel, W7

    But are you running 64bit NX?
  4. mikebuchter

    NX (x64) w/ Excel, W7

    I know that Excel 2003 is not compatible with NX x64 on Windows 7 x64, now for Excel 2007+ is 64bit required for NX x64 or can you use 32bit versions for 2007 and higher? We would like to switch everyone to NX x64 however we don't want to buy the x64 version of Excel for everyone. So the main...
  5. mikebuchter

    NX7.5 32bit memory issues

    I recently had to switch back to 32bit NX7.5.5.4 and when I try to open a large assembly file it keeps crashing by just closing the program. I have attached my system information where it has the Maximum Memory Allocated 195mb with a possible 12335 available is there a way to change this and...
  6. mikebuchter

    Bringing NX models into SigmaNEST

    We are using NX7.5 and our parts are importing fine. However, we could not get NX8.0 to import but they are still working on that.
  7. mikebuchter

    NX Export PDF function and printing

    Got it fixed, I guess it would help if I installed NXPlot!
  8. mikebuchter

    NX Export PDF function and printing

    I recently was using NX 7.5.4.4 (x64), I have since uninstalled that version and I am now running NX 7.5.5.4 (x32), I am not able to print or Export PDF's. This worked fine in the 64bit version. When I go to print it says UGII_SDI_BASE incorrect, but when I checked the path it is correct...
  9. mikebuchter

    NX7.5 Spreadsheet Issues

    I had a spreadsheet that created in NX7.5 (32bit) w/ Excel 2003, & XP (32bit), when updating the formulas it takes less than a minute. I have since gotten a new computer Windows 7(64bit), NX7.5(64bit) & Excel 2003 (32bit), when converting this file over everything is still fine. Now I created...
  10. mikebuchter

    NX 7.5 Part Families

    John, no these components do not exist, I would to create new components off of these generic parts.
  11. mikebuchter

    NX 7.5 Part Families

    I have an assembly with 3 components named generically. Top, Bot, Middle. I would like to create a part family and rename the generic names to official names. I have tried this a few times but it seems to be looking to replace the generic named model with the official named file. Does anyone...
  12. mikebuchter

    NX 7.5 Expression limits?

    This is the screenshot of the full expression formula.http://files.engineering.com/getfile.aspx?folder=43e12183-7c6c-42b7-afb6-9ec1885fbbe1&file=ScreenHunter_02_Jan._31_16.28.jpg
  13. mikebuchter

    NX 7.5 Expression limits?

    Here is a screenshot of the issue. We are running NX7.5.4.4 MP6.http://files.engineering.com/getfile.aspx?folder=f3a3891c-3e9c-4342-8a6c-48240e6e8080&file=ScreenHunter_01_Jan._31_16.28.jpg
  14. mikebuchter

    NX7.5 x64 and Excel 2003

    I know there is an issue with being able to create a spreadsheet from NX with NX7.5 x64 and Excel 2003, W7 x64, but I wanted to know if there is also performance issues. When I edit my spreadsheet and hit update it takes atleast a minute before it begins to process the changes. We have done...
  15. mikebuchter

    NX7.5 Assembly Constraints

    I forgot to add that it basically seperated the constraints how it was when Mating Conditions were used.
  16. mikebuchter

    NX7.5 Assembly Constraints

    I remember in the NX5-7.5 transition class the instructor showed us the assembly constraints per individual part. He clicked on the part and then I thought it showed the constraints under dependencies. I know this was something that I was looking forward to when switching over but now I can't...
  17. mikebuchter

    NX 7.5 Expression limits?

    It is cut-off, when you hover over it the pop-up window shows it the same way, if you make any changes with it "cut-off" it will not accept the expression. The only way to get it back is to reject edit then the full expression shows up.
  18. mikebuchter

    NX 7.5 Expression limits?

    We have a few really long expressions, and when we go into expressions dialog box and click on that specific expression, the formula is cutoff, we have to reject the edit and then go back into it, and the full formula is there. Anyone else have this problem or is this some kind of bug, this...
  19. mikebuchter

    Best Practice UG/NX mixed units

    We now have seeds that you can input in either inches or metric. We have it setup in expressions. UNITS ="English" or "Metric", Scale = IF (UNITS = "Metric") THEN (25.4) else (0). Every dimension must be divided by the scale.
  20. mikebuchter

    3GB Switch NX5

    Yes many of the files are 1-5mb and they do include the drawing sheets. Where can I check how much memory I am using?