Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: rmore
  • Order by date
  1. rmore

    Motor capacitor failures

    We have a problem with capacitor failures in the field. Some key information: * The problem occurs at 220V 50/hz locations. No complaints at 120V/60Hz locations. (different manufacturers for 50hz vs 60Hz motor). * This is happening at a number of sites. * Failures occur after running about a...
  2. rmore

    IP65 rated HMI in NEMA4X Stainless steel enclosure

    Thanks for the warning. We are aware of the obsolescence. Assume that the question also applies to UL 60335-2-40. Any advice?
  3. rmore

    IP65 rated HMI in NEMA4X Stainless steel enclosure

    UL 1995 Heating and Cooling equipment (outdoor use)
  4. rmore

    IP65 rated HMI in NEMA4X Stainless steel enclosure

    Is it acceptable to use an IP65 CE rated HMI (24VDC) with a stainless steel enclosure (NAME 4X) in a UL listed product? If so, what needs to be considered in order for this combination to pass muster with UL?
  5. rmore

    Problems with HMI's installed outdoors

    Does anyone have any real-world examples of problems occurring when color LCD touchscreen HMI's are installed in equipment outdoors?
  6. rmore

    Do low voltage sensors need UL registration in a UL listed product?

    We have a product with a PLC that we are considering for UL listing. There are a number of industrial pressure sensors with 1-5V outputs powered from a fused 24VDC supply. Do we need to use UL registered sensors in order for the products controls system to be listed?
  7. rmore

    Input protection for 460V 3-Phase DC power supply

    We have a 460VAC 3 Phase DC power supply in a design that has internal fuses protecting the line inputs. We have a 20A D characteristic breaker on the incoming power. Additionally, we have 3A fuses external to the power supply. The installation instructions for the supply state the following...
  8. rmore

    Electrical assembly training

    We build industrial equipment. No military or government contracts.
  9. rmore

    Electrical assembly training

    We are hiring some new employees to do machine wiring and electrical enclosure assembly, as well as, machine testing and troubleshooting. I am looking for ideas to send to our production manager for outside training. The topics would include wiring and cable assemblies, control boxes...
  10. rmore

    Changing the Modbus-RTU slave address on Rockwell Micro 820

    That works. And it's fairly straightforward once the MSG_CIPGENERIC function is properly configured. I am now able to change the Modbus RTU unit addresses from the HMI or via jumpers on PLC inputs. I was also able to use the same method to set the Ethernet IP address. Thanks You!
  11. rmore

    Changing the Modbus-RTU slave address on Rockwell Micro 820

    I am using a Rockwell Micro 820 configured as a Modbus-RTU slave device. Is there a way for the user to change the slave address without giving him access to the application code?
  12. rmore

    Implementing WITSML with a PLC

    Good idea. I've reposted to the Petroleum Engineering General Discussion Forum. Thanks.
  13. rmore

    PLC data transfer using WITSML protocol

    We have a customer in the oil and gas industry that wants us to provide our equipment with “WITSML Communications Protocol via RJ-45 port". Our equipment is controlled by an Allan Bradley Micrologix 1400 PLC with a Modbus port. What is necessary to provide the WITSML protocol that the customer...
  14. rmore

    Implementing WITSML with a PLC

    IRStuff. Thanks for the response. I will check out the standard from Energetics. In the meantime, I'm hoping to get some guidance from someone with practical experience with the WITSML protocol being used to transfer data generated by a PLC via it's Modbus port.
  15. rmore

    Implementing WITSML with a PLC

    We have a customer in the oil and gas business that wants us to provide our equipment with “WITSML Communications Protocol via RJ-45 port" I did some research to determine that WITSML is an XML based protocol and assume that RJ45 port is an Ethernet port. Does anyone have experience...
  16. rmore

    Under what conditions is it OK to NOT include a line reactor in an application with a VFD?

    I need to justify adding the cost of line reactors to a product we are developing that uses a VFD and have a few questions that I'm sure are going to come up. Note: Our machine requires a dedicated branch circuit. 1. Under what conditions is it suitable to NOT include a line reactor (and it's...
  17. rmore

    How to manage relationship between hardware and program revisions.

    This topic came up recently in house. What are the pros and cons of updating the hardware revision whenever a change in the software occurs? Is it better to manage the revisions separately? If so, how do you link these changes in your engineering change process?
  18. rmore

    Sheet metal finishing standards

    Unfortunately, our supplier looks at us with a blank stare when we ask about their quality specs. We had something similar to "Acceptable Workmanship" as a requirement, but there's a definite difference of opinion between our QC guys opinion of what that is and everyone else's. So we need to...
  19. rmore

    Sheet metal finishing standards

    I am interested in machinery and appliance enclosures, shrouds, etc. We are attempting to come up with a spec for our quality department to use to judge the quality of finished sheet metal cabinet parts from our supplier.
  20. rmore

    Sheet metal finishing standards

    Are there national quality standards that cover sheet metal fabrication and finishing?

Part and Inventory Search