  1. abo2eyes

    how to measure watt hour and volt ampere reactive hour

    what is the diffrence in construction ? HELP SYRIA
  2. abo2eyes

    SIEMENS GT 94.02

    so what about anti surge ? any one here worked in this type ? HELP SYRIA
  3. abo2eyes

    SIEMENS GT 94.02

    hello what will happen if we did not close compressor wash drains when we are starting up the turbine ? HELP SYRIA
  4. abo2eyes

    VIBRATION

    what is the reasons of increasing vibration ? why increasing of MVAR increases the vibration ? HELP SYRIA
  5. abo2eyes

    siemens GT 94.2 125 MW combined cycle

    yes circuit breaker opens when frequency load control and the speed control become active and the turbine be operated in 3000 rpm not connected to the grid HELP SYRIA
  6. abo2eyes

    siemens GT 94.2 125 MW combined cycle

    we have 7 or 8 control systems 1.start up control start from 33% from nominal speed means from 100 rpm means from opening the control valve to 2850 rpm means when the excitation is started 2.speed control from 2850 to 3000 rpm (when the turbine is connected to the grid ) if the turbine takes...
  7. abo2eyes

    Black Start Generators Wiring Diagram/s

    what about the manufacturer of your generator recommendation it is not standard it differs from one type to another so u specified your load with 1.25MVA select your manufacturer and see the recommendation if u are making a new design of diesel generator u have to calculate your emergency loads...
  8. abo2eyes

    Black Start Generators Wiring Diagram/s

    what about the manufacturer of your generator recommendation it is not standard it differs from one type to another so u specified your load with 1.25MVA select your manufacturer and see the recommendation if u are making a new design of diesel generator u have to calculate your emergency loads
  9. abo2eyes

    siemens GT 94.2 125 MW combined cycle

    really we have 8 control modes i wrote our turbine type Siemens 94.2 but unfortunately i did not find valuable details about this turbine in the internet
  10. abo2eyes

    siemens GT 94.2 125 MW combined cycle

    i am sorry but i did not know that my language is too bad like this really i think u cant understand me cause your native language is english !!!!!!!!!!!!! my question is i have a siemens GT 94.2 125 MW we got 8 speed control systems for start up - load limit generator - temperature control...
  11. abo2eyes

    siemens GT 94.2 125 MW combined cycle

    hello any body know's the answer ? i know that is turbine in operated in iran - dubai - south africa - egypt - Occupied Palestine
  12. abo2eyes

    Radial turbine maximum pressure ratio

    really i do not know but in siemens 125 mw 94.2 the ratio is 1:10
  13. abo2eyes

    scrubber

    sorry i do not know what is peers ? i did not hear about before
  14. abo2eyes

    siemens GT 94.2 125 MW combined cycle

    why two system control operated in same time after that the turbine immediately trip no one know why this is happens ? 1. frequency load operation 2.speed control
  15. abo2eyes

    Can A Motor Be Run On Lower/Higher Than Rated Frequency?

    really i appreciate that sorry English is not my native eng carlos i understand now that the diffrence in manufacturing between both 50 hz and 60 hz is the winding way is that true ? secondly how to re-desgin the motor to operate on 50 hz ? thanks
  16. abo2eyes

    Can A Motor Be Run On Lower/Higher Than Rated Frequency?

    so u mean i derate the motor to 4 kw cause the torque is decrease cause of decreasing the voltage ? secondly i do not know the roles to make new winding but with 50 hz? really i donot know the difference in manufacturing between the both motors with 50 hz and 60 hz
  17. abo2eyes

    Can A Motor Be Run On Lower/Higher Than Rated Frequency?

    really i am puzzled when i have my winding motor burned with 60 hz rating what i have to do to make new winding but with 50 hz rating ???????
  18. abo2eyes

    DB for hotel in Australia

    first time to hear about db but i think it is good idea to make it on thecelling