  1. dmersim

    Calculating Frequency for Light Gauge Building

    Hello, I'm working on a building where I need to calculate the wind load of a building. The walls are comprised of cold formed steel with gyp for shear walls. I need to calculate the frequency of the building. My two questions are, how can I determine whether the building is rigid or not...
  2. dmersim

    Best Brace Layout Question

    There will be compression in the braces because it is not a X brace, it is in separate bays. I believe there is no impact as the loads are all accounted for in the same way whether the braces are diaganol in the same/opposite direction. I am not sure if it impacts my foundation.
  3. dmersim

    Best Brace Layout Question

    Follow up to my question, here is another screenshot of a different layout for the braces. Thank you http://files.engineering.com/getfile.aspx?folder=16527247-5ae3-4b71-8952-191550264d2f&file=brace2.JPG
  4. dmersim

    Best Brace Layout Question

    Hi everyone, I am designing a RAM model that will incorporate some brace frames. My question is is there a optimal way of laying them out for best efficiency? Please view the screenshot to get a better understanding of my question. I have 2 bays with the single brace. Should I have one of the...
  5. dmersim

    CMU properies

    Dik, I understand, what is f'm typically with the combination of the grout and the block?
  6. dmersim

    CMU properies

    Hello, I am making a RAM model that I need to model in a CMU wall for. I read online it is more accurate to use the "other" option instead of a concrete wall. When going into the other option it asks for the properties of CMU. One of the properties is the modulus of elasticity. The equation...
  7. dmersim

    R Value for snow loads in Tedds

    okay, as a followup question - If i already know my Ct value, how does the R value effect my snow load?
  8. dmersim

    R Value for snow loads in Tedds

    Heres a picture of the menu where it asks for R
  9. dmersim

    R Value for snow loads in Tedds

    Hello, I have a question about the R value (Thermal Resistance) in Tedds when referencing ASCE 7-05. How do you calculate it? My Ct value is 1.00 but i dont see a way to calculate thermal resistance which is defaulted at 30 in Tedds. Sorry if my formatting isnt correct this is my first post...