Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Yazan Atoum

    steel retrofitting to a water tank

    The water will be filled with oxygen for recycling, I don't really know the process of water filtration, but the condition will be a bit harsh on the weld, that made me excluding it as it cannot be guaranteed. I agree with JedClampet, the evaluation of such structures is not a straightforward...
  2. Yazan Atoum

    steel retrofitting to a water tank

    So everyone also agrees that welding from the inside will be problematic as it will corrode, if not this will be the easier option. The problem is that when beams at two levels were welded at the exterior face of the tank, it didn't solve the problem and the water load bent the beams to the...
  3. Yazan Atoum

    steel retrofitting to a water tank

    SAIL3 yes tension, hinged connection.
  4. Yazan Atoum

    steel retrofitting to a water tank

    The material of the tank is steel plate with 6 mm thickness. and the water in not potable.
  5. Yazan Atoum

    steel retrofitting to a water tank

    Hi guys, I have a water tank with a depth of 4 meter and planar dimensions of 9X4 meter squared the problem when it is filled with recycled water to a depth of 3.5 m, what happened in reality that the tank bloat and the walls tend to bend to the outside, I am thinking of a retrofitting method...
  6. Yazan Atoum

    Circular base plate design with opening

    I have a circular base plate with a opening as in the picture, I need to find the neutral axis location for bending on the plate to design for the maximum tension force per bolt, I believe most of the bolts will be in tension and a block of the steel plate will take compression. can anyone...
  7. Yazan Atoum

    Slotted connections in steel members

    Hello Engs. I have a connecction between two steel beams, one resting on another, it's bridging between two buildings so movement in 2 direction have to be considered. I had come to this detail where the bottom flange has a long slotted hole while the top flange of the other beam has oversized...
  8. Yazan Atoum

    Normal and destabilizizng load

    What is the difference between normal and destabilizizng load in BS 5950-1 as per below table. Can I assume DL, LL and Wind load as Normal loads?
  9. Yazan Atoum

    Lateral torsional buckling

    Can you guys advise about the Lateral torsional buckling length for a cantilever beam in a lightweight roof, which is torsionally braced with knee bracing attached to purlins at interval of 3 meters. Shall I take LTB length as 3 m or shall I take it as a percentage of 8.7 m
  10. Yazan Atoum

    BLAST LOAD FOR STRUCTURE

    Hello Engineers, I am working on a military building, and this building is required to tolerate blast, anyone knows which load combination should I use for Blast loading? are there any references which combine Blast load with other regular loads (Dead,live, Wind etc...) Thanks a lot
  11. Yazan Atoum

    Free-Standing Stair

    Hello Engineers, I have a steel freestanding stairs to design, is there any additional consideration I have to take into account rahter than designing a simply supported stairs? is it right that I need to apply 2-3 live load cases to give max tension in higher flight and max compression in the...
  12. Yazan Atoum

    ASCE-05 Wind load on louver steel structure

    Hello Guys, I have a question regarding Wind load calculation using ASCE7-05 on a louver supporting system as shown in the attached picture, for this type of structure shall I treat it as an open sign & Lattice Frameworks and use the Cf factors in Figure 6-22 or shall I go for the Solid free...
  13. Yazan Atoum

    For IBC 2006 TABLE 1604.3 DEFLECTIO

    I am asking for wind drift, when I check for the limits in IBC Table 1604, do I calculate the drift based on D+0.5L+0.7W or W solely. That's all, thanks
  14. Yazan Atoum

    For IBC 2006 TABLE 1604.3 DEFLECTIO

    Can you please guide me to the refernce, I always design for the limit D+0.5L+0.7W but It's written in IBC table 1604.3 S or W or 0.7 W of components and cladding
  15. Yazan Atoum

    For IBC 2006 TABLE 1604.3 DEFLECTIO

    I know I can do that, but I want a codified answer, I don't want an overdesgined approach.
  16. Yazan Atoum

    For IBC 2006 TABLE 1604.3 DEFLECTIO

    For IBC 2006 TABLE 1604.3 DEFLECTION LIMITS, It states the limits for (S or W), in this case do I have to consider the effect of the wind load solely on the structure or I can calculate the deflection based on the criteria: D + 0.5L + 0.7W in Design Guide 3 ?
  17. Yazan Atoum

    Lateral torsional buckling

    TheRick109, I wouldn't be a structural engineer if I haven't known these basics, please reread my question carefully, I am talking about the ability of secondary beam with a shear connection to provide full LTB resistance to the main girder at the inflection point of the negative moment, where...
  18. Yazan Atoum

    Lateral torsional buckling

    Hello Engineers, I have a question. For a composite slab I used to design the main girder's bottom flange to be unbraced for its whole length, but one engineer told me that this is extremely conservative and secondary joists with depths around >= 1/3 depth of Girder would provide bracing for...