Search results for query: *

  1. stevencress

    Distorted residential power, only at night?

    You might be able to take a small portable radio tuned to the hi end or low end of the AM dial and walk down the street if front of the 14 houses and see if the noise lever increases in front of one house. Even better is to check at the utility meters. Sounds like a nearby neighbor may have a...
  2. stevencress

    Giants-Cowboys power outage

    We have been blamed for stranger things.
  3. stevencress

    Giants-Cowboys power outage

    Does anyone know the details of what happened to cause the Giants-Cowboys power outage?
  4. stevencress

    14 % Harmonic Distortion at residential customer

    Chances are the problem is in your house. If you have a battery powered portable radio, turn it on and see if you hear loud buzzing noise at the low end of the AM dial, then check the high end of the AM dial. Nothing? Carry the radio to various rooms and see if you can detect the LOUD BUZZING...
  5. stevencress

    Transformer popping noise

    The transformer was probably manufactured in Mississippi. What you are hearing is a redneck fire alarm. They enclose a bag of popcorn inside the transformer, when it pops, the transformer is overheated.
  6. stevencress

    Assistance in sizing XFMR

    The "Running Mode KVA Eq" looks like a good estimate of running load. Two of these equals 2 x 133 kva = 266 kva. All of the other misc load will run around 20 kva. A 300 kva 3-phase transformer would handle the running load, but I would chose a 500 kva transformer to handle the running load...
  7. stevencress

    Electrical power question

    question 1 The plant's electric bill is based upon a charge for kwhr consumed during the month and a charge for peak monthly kva. question 2 Dont worry about kvarh or amps, both are proportional to kva. The utility bills for kwhr and peak kva. question 3 See the answer to question 2...
  8. stevencress

    relay test set 3-ph module

    We have an old relay test set, RTS-150 made by EIL (now Ametek), it contains an add-on module which gives the test set 3-phase capability. But we don't have any instructions on how to use the module. Can anyone help us with wiring this module into the test of a 2.5 element transducer? Thanks
  9. stevencress

    Oil filled vs Dry type Power Transformer at marine enviroment

    Just remember. If an oil filled unit ruptures, and oil enters the marine environment, President Obama will be looking to kick your a**.
  10. stevencress

    test 2.5 element transducer

    We have an old relay test set, RTS-150 made by EIL (now Ametek). Having trouble wiring up 2.5 element watt transducers to this test set so that it can be tested with single phase amps and volts. Can anyone tell us how to wire the 12 lugs? Thanks
  11. stevencress

    Smart Grid

    Power companies are no longer run by engineers. Accountants, lawyers, and Women's Studies grads are now in charge. That explains why the Smart Grid is so exciting to everyone except those of us who still know what the hell is going on.
  12. stevencress

    Utilization of Electrical Energy in a large Industrial pharmaceutical

    Call the power company. They probably have an industrial engineer or an ee who works with their industrial customers. He will be familiar with the electric rates. He can probably meet with you and give you some good ideas.