  1. edison123

    Can two VFD's run in parallel

    Jeff With 250 A drive, what is the lowest current it can be used for ? Vendor says 10% i.e. 25 Amps. Muthu www.edison.co.in
  2. edison123

    Continuous monitoring of stator insulation when the machine is offline

    Never seen off-line 24x7 IR monitoring of windings. Properly sized space heaters keep the IR values up and you check in periodically. Don't see the point of continuous monitoring. Muthu www.edison.co.in
  3. edison123

    Can two VFD's run in parallel

    Thanks, Jeff. The vendor did confirm this Fiji drive does not have that capability of 2 in 1 power output. Muthu www.edison.co.in
  4. edison123

    Can two VFD's run in parallel

    Thank you, all. Our supplier is going to ask the drive OEM about this possibility. Muthu www.edison.co.in
  5. edison123

    Standard for Maximum Lifespan

    Agree with Gr8blu. No standards will specify life of electrical machines since it depends on how they are operated, are maintained etc. I have been repairing machines from 1930s vintage to 2024 and I know where the OEMs are cutting corners to cut costs over the years. Previously the designer's...
  6. edison123

    how to set PID control in VFD that operate a centrifuge pump transporting juice being concentrated

    Agree it's apples and oranges, but these oranges still had 90+ efficiency, not 50 to 60%. May be using higher efficiency cage motors off-sets whatever additional VFD loss but my clients are switching over to VFD due to utility cost saving, less maintenance headaches and option of variable...
  7. edison123

    Can two VFD's run in parallel

    For no-load open shaft testing various motors ranging from 50 HP to 1500 HP with maximum no-load current of 500 Amps at 415 V, 50 HZ, I am planning for to go for VFD. If I buy two identical 250 Amps drives, can I parallel them on the output side for 500 Amps? This gives me an option of using...
  8. edison123

    how to set PID control in VFD that operate a centrifuge pump transporting juice being concentrated

    In India, I have seen a booming market for VFD's. Many of my clients in traditionally conservative process industries like cement, chemical. steel, sugar, glass making, tyre manufacturers etc are replacing their time tested DC and slipring motors with VFD driven AC motors in the last two...
  9. edison123

    Temperature rise of a coolant - Generators / Motors

    API 541 table those pressures should be ≤ and not ≥. Muthu www.edison.co.in
  10. edison123

    Temperature rise of a coolant - Generators / Motors

    Design of electrical machines cooling system is more of an art than science. The only goal of any air/hydrogen (primary coolant) to air/water (secondary coolant) cooling system is to have the machine inlet air/hydrogen temperature under 40 deg C, the limit defined by standards. In air/hydrogen...
  11. edison123

    500 RPM 8000 kW hydro generator dimensions

    Rod 12 pole machine Cons: Less efficient, costlier, bigger footprint, heavier (crane), long lead time. Pros: No gear box. Less noisy. Less wear & tear hence less maintenance cost 4 pole machine Cons: Gear box with efficiency loss. Noisier. More wear & tear hence more maintenance cost. Pros...
  12. edison123

    500 RPM 8000 kW hydro generator dimensions

    Hi Walt Yes, it's a diesel. The client is an IPP and bought this used 6.6 KV generator which we rewound for 11 KV to match his other 11 KV DG sets. Running well for two years now. Rod Unlike 2,4 or even 6 pole, multipolar generators are custom designed and built and the few OEM's may not...
  13. edison123

    500 RPM 8000 kW hydro generator dimensions

    8 MW, 8 pole open ventilated generator rewound (6.6 KV to 11 KV conversion) in our shop. 30 tons / 12 ft x 8 ft x 9 ft (H) app. A similar 8 MW, 12 pole machine will likely have 20% bigger size and would weigh probably 30% more. Muthu www.edison.co.in
  14. edison123

    Does anyone use NTC resistors to limit inrush current on single phase AC motors as a soft start?.

    NTC resistors OEM links (pdf alert) https://www.eaton.com/content/dam/eaton/products/electronic-components/resources/technical/eaton-ntc-thermistors-app-note-elx1247-en.pdf https://cdn.soselectronic.com/productdata/71/15/e533b543/s-237-5-b57237-s509-m.pdf Muthu www.edison.co.in
  15. edison123

    Gas turbine high vertical vibrations at 1X

    5100 RPM (85 Hz) GT driving a 3000 RPM (50 Hz) generator via a gear box is showing high vertical vibrations during startup (after a year-long shutdown) in GT front bearing (NDE) as below. GT rear bearing (DE) also showing similar high vibrations. Both GT and generator white metal bearings are...
  16. edison123

    Calculated neutral current not matching measured neutral current

    Thanks jghrist. Got it. Would it work if another phase is taken as 0 deg? (Wish I could give more LPS). Muthu www.edison.co.in
  17. edison123

    Calculated neutral current not matching measured neutral current

    Thanks jghrist . Your calculation tracks what I measured at neutral. If I may ask, how did you arrive at 0, 119, 119 angles ? waross - Input voltages are pretty much equal. It's regulation that is the issue. I had the utility guy measure the voltages at their transformer end, which is about 600...
  18. edison123

    Calculated neutral current not matching measured neutral current

    Neutral current at low load was 2 Amps jghrist - The angles between the phasors A1, A2 and A3? How would you plug in these angles in your Excel sheet? Muthu www.edison.co.in
  19. edison123

    380V/60HZ/3PH POWER SUPPLY

    How many leads are on the motor terminals, 6 or 9? Post a photo of the motor terminal box. Muthu www.edison.co.in