  1. GenB

    ASME Section VIII, Div-1 Pressure vessel

    ASME Here: ASME is a construction Code if so, once leaves the shop and get loosed, is not possible to certify a product. In your case is worth, you shipped the vessel and possible to another country. Unless the Inspection Agency authorize it and if the proper documentation exists it may be...
  2. GenB

    Design code - low pressure

    If looking for the lightest. the best bet is to run calcs and analysis per ASME VIII-Div 2 whether is certified or not. General Blr. CA,USA
  3. GenB

    Torquing

    R6155, you're right. "You must always control it" but the right bolts are allowed, studs better. General Blr. CA,USA
  4. GenB

    Hydrostatic test.

    welding, NO NO NO mechanical joints dripping and Boiler tubes dripping, may be accepted. may be acceptable per each Inspectors criterion. better NO Leaks at all. General Blr. CA,USA
  5. GenB

    ASTM E309 and A106 Gr B pipe

    probably for cracks or lamination assurance, I would ask for recommendations here, Houston TX ClientServices@apexinspections.com these companies are usually near refineries, power plants General Blr. CA,USA
  6. GenB

    Hi everybody, I have a question

    Hi. I got to say something, UG-10 does not apply to this type of issues. The ASME most likely will reject its use on code Works, it locks tests that cannot be done afterwards. My opinion only. General Blr. CA,USA
  7. GenB

    When is a safety valve required on an air reciver

    per ASME Code, your air receiver does not need a fire rated safety r.valve but a pressure relief valve. consult your local fire chief and fire Codes to asses fire safety. If you want to instal an alternate safety for fire, you can probably use a Fuse Plug, the same that are used on Boilers...
  8. GenB

    When is an unfired steam boiler not a heat exchanger?

    Per ASME this is not an electric boiler. There are 2 types of electric boilers, Immersed resistance element and electrode. The above post mentions external heat therefore is is a Fired steam boiler and requires full power boiler certification and most jurisdictions (surely US&Canada)will...
  9. GenB

    Inconel 625 approved for superheater but not boiler?

    The amount of steam you want to produce makes a difference in designing a boiler of any type, fuel or electric powered. General Blr. CA,USA
  10. GenB

    ASME SECTION VIII, DIV.1 flanged pipewell calculation question

    This is a non conventional design and may require a destructive test or further analisis Acceptable to the AI. 'cant use a modified flange as ANSI Std. Even if camouflage the calculations. General Blr. CA,USA
  11. GenB

    Electric boiler and explosion

    nonsense.good luck. General Blr. CA,USA
  12. GenB

    Cooling rate during PWHT

    Metengr. But you can hire the best pwht company, they will give you good advise but the stamp holder bears the final responsaibility as he has to have and use his PWHT QC procedure. Just commenting since you are the best on this subjects. General Blr. CA,USA
  13. GenB

    Hammer a vessel's seams during hydro?

    Molten. I think you mean Unless the pressure is very high! General Blr. CA,USA
  14. GenB

    Electric boiler and explosion

    It's not to do with the pressure vessel but electrically. Explosion proof means you will use components suitable as NEMA 4X and choice of type and class as Div 1 class 1... Used where highly flammable gasses are present, gasoline, hydrogen General Blr. CA,USA
  15. GenB

    Package Boiler Installation

    Get couple estimates from boiler or mechanical contractor.from water treatment all the way to start up. General Blr. CA,USA
  16. GenB

    Weld bead misalignment

    Certainly did not pass the Visual examination either. In ASME Code you should certify it by virtue of a NonConformance Report. Of course your A.I. has to agree and sign off. Some one mentioned to amend the WPS but I think you cannot have that mishap in your quality system. Regards. General Blr...
  17. GenB

    injecting steam in fuel gas line of boiler

    I Don't think you got the job. General Blr. CA,USA
  18. GenB

    Figure UG-34 (g)

    Yes land that you see is for a very thick plate that can be left unwelded but there are other rules that govern. Cut your plate at 35-45° and weld per Code. General Blr. CA,USA
  19. GenB

    ASME BPVC Sec. VIII Div. 1 UG-36(C)(3)(-C)

    if you stagger the fittings you have to prove reinforcing. General Blr. CA,USA
  20. GenB

    steam quantity from a tank

    According to the size of the tank and water contain, the most heat absorption and amount of steam is in the approx. 200000Btu.hour and 200 lbs.steam per hour. So a STD 3/4 in pressure relief valve will do. You choose the pressure depending g of the system pressure plus 10% . I would use a...