  1. EngineerEIT

    how much above "capacity" you feel comfortable going over?

    The below video should be enlightening and give you the necessary background information to let you make this determination using your engineering judgement. Link
  2. EngineerEIT

    Seismic loads with Profis

    You are referring to the ductile failure requirement in Appendix D, Read this blog post: Link
  3. EngineerEIT

    Exterior Load Bearing Walls - OOP Wind + Uplift

    I understand multiple load combos exist and I understand the difference from tributary area and effective area. I think everyone knows that the out-of-plane pressure on the wall should be C&C but what about the uplift from the roof trusses? I am asking when you design the load bearing wall...
  4. EngineerEIT

    Exterior Load Bearing Walls - OOP Wind + Uplift

    Per ASCE 7-10: When you are designing wood load bearing studs supporting low slope wood roof trusses, do you include an uplift value in your axial load determination due to wind? Do you use MWFRS (say Cp from Figure 27.4-1) or C&C? Say tributary/effective area is less than 700sf. For the...
  5. EngineerEIT

    Equal amounts of reinforcement in doubly reinforced concrete grade beam

    Reinforcement above the neutral axis (for positive bending) will be in compression. For strains less than the yield strain, the force will be equal to the strain in the bar * modulus of elasticity (F=E*ε, hooke's law).
  6. EngineerEIT

    60° Angle Legged Self Support Tower

    What is failing exactly? Legs in compression? Diagonals? Bolts? It's been a few years since I've used tnxTower but I don't recall anything "special" about 60deg legs besides using the built-in tool to create the leg shape.
  7. EngineerEIT

    steel floor deck composite requirements

    Studs can help the gravity load carrying capacity of the composite deck. See the below catalog from Vulcraft. Link
  8. EngineerEIT

    Diaphragm Aspect Ratio For Steel Deck?

    I believe chapter 16 of the California Building Code has some limitations similar to what deck manufacturers specify in ESR reports.
  9. EngineerEIT

    Composite Beams

    This old modern steel construction article gives some guidance on designing composite beams with slab openings. Link
  10. EngineerEIT

    Removing X-Bracing for New Doorway

    Assuming you aren't in a seismic area. Look at replacing the braces with a chevron brace and put door in the middle of the bay. Or try a single brace if the door needs to go towards the end of the bay.
  11. EngineerEIT

    Structural Steel- Moment Connections

    Here are a couple of webinars which discuss these types of connections: https://www.aisc.org/education/continuingeducation/education-archives/flexible-moment-connections-n28/ https://www.youtube.com/watch?v=SdoZaCu7YLo
  12. EngineerEIT

    AISC 9th vs AISC 14th steel manual

    You should design based on the building code adopted by the state/locality the project is located in. C2.3.1 is related to the "Direct Analysis Method" which you would use to design your structure for strength considerations. The 20% stiffness reduction does not need to be taken for...
  13. EngineerEIT

    Comparing Brace Configurations

    The beams in configuration A will have to be designed for the accumulating axial load as the horizontal component from the brace above will have to travel through the beam to the brace on the opposite side. Configuration B has a more direct load path and the beams would only need to be designed...
  14. EngineerEIT

    AISC 15th vs 13th Edition - HSS

    ASTM A500 GR C (50 ksi for square/rect, 46ksi for circular) is the preferred material for HSS per the 15th edition manual, hence the use of Fy=50 ksi in the 15th edition manual. See the recent article from modern steel construction...
  15. EngineerEIT

    Miami Pedestrian Bridge, Part I

    Here is a link of the proposal from the design build team. I have a hard time imagining that the project would progress to construction without a design that considered the simple span condition before the the back span was placed and the two were tied together. I don't design bridges but aren't...
  16. EngineerEIT

    Linear Interpolation of Wind Speed Maps (ASCE 7-16)

    You can use the below tool from ASCE and find the ASCE 7-16 wind speed using the address or longitude/latitude of your project (wind/tsunami values are free to use) https://asce7hazardtool.online/
  17. EngineerEIT

    Steel Channel Identification

    This seems like a channel we would sometimes use to reinforce monopole telecomm towers during my time in that industry. We referred to them as "aerochannels". They are so heavy due to the restriction of fitting on the flats of these towers, which can get rather small near the top of the tower...
  18. EngineerEIT

    Mechanical opening needed after fabrication/erection

    Thanks haynewp, I knew there was something I wasn't thinking of
  19. EngineerEIT

    Quick Sanity Check Requested - Removing an internal wall in a wood frame building

    All of the length of the wall past the start of the opening would probably be ineffective to behave as a shear wall. The left end could also be ineffective depending on the height-to-width ratio.
  20. EngineerEIT

    Gusset Plate Stiffener Design

    I would think a 5/8" thick angle could take a ~2.25 kip (10 kN) reaction with no trouble. Can't you reduce your considered eccentricity by considering the centroid of an assumed bearing stress (uniform?) on the angle leg and taking the eccentricity to the edge of the fillet of the angle? Also...