Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Berenger

    Thermal Relief Load

    Hi all, My question is straight forward. Can you size a thermal relief valve FOR GAS ONLY SYSTEM? If yes, how do you calculate the load requirement? I have gone through API 520 and 521, and nowhere do they discuss or explain thermal relief for a gas only system. I know 521 section 5.14 talks...
  2. Berenger

    PSV Sizing Flowrate? Actual Vs Design

    Hi experts, I have a few questions about PSV sizing. I got some drawings and datasheets from a vendor for a fuel gas skid and I don't think the vendor calculations are correct. I will appreciate if you can help me with answers to the following questions: (1) Fuel gas skid is designed for a...
  3. Berenger

    Can a Thermal Relief Valve be Discharged Into the Pump Suction Line

    Sorry, was out of the country on vacation. Here is a PFD of what I've been trying to describe. The safety valve in question is the one in red. As you can see, it is not discharging directly into the pump suction - there is a valve between the discharge and the pump suction. Also, note the...
  4. Berenger

    Can a Thermal Relief Valve be Discharged Into the Pump Suction Line

    The suction is around 100 psig and the discharge is 700 psig. The pipe ANSI ratings are higher on the discharge piping as can be expected (150 vs 600). However, the pump flanges are ANSI 900. Also, don't overlook that there is a bypass around the pump. I assumed that even if we need to relieve...
  5. Berenger

    Can a Thermal Relief Valve be Discharged Into the Pump Suction Line

    Yes, there is a TRV around the discharge valve too.
  6. Berenger

    Can a Thermal Relief Valve be Discharged Into the Pump Suction Line

    Latexman, thanks for the reply. I did not show the valves on the discharge line because I did not think it was important to the question. However, we DO have valves on the discharge line.
  7. Berenger

    Can a Thermal Relief Valve be Discharged Into the Pump Suction Line

    I have a facility set up as shown in the attachment. It is a crude oil pump station. Oil comes in, it is metered and it is pumped to another facility. We have valves on the suction and discharge side of the pump. To account for thermal relief we have installed a TRV on both the suction and...
  8. Berenger

    Hysys Calculation

    You can use dynamic simulation in Hysys to model the problem. See the Hysys manual or contact Hysys helpdesk.
  9. Berenger

    Liquid Pump Blocked Outlet Sizing Flow Criteria

    Yes, @ georgeverghese, the max developed pressure will exceed the pipeline MAOP. Not by much, but by 60 psig. Littleinch, the pumps are positive displacement pumps. I think the full flow is required to size the safety valve on the pumps. I use API 521. Thanks, to both of you. I think I have a...
  10. Berenger

    Liquid Pump Blocked Outlet Sizing Flow Criteria

    Thanks, LittleInch, Yes, the flowrate has doubled to 144000 barrels per day because the client wants a 100% design factor in the facility (first time I’ve heard of that). Anyway, it seems like there will be more crude passing through the facility BUT they can’t tell, definitively, how much...
  11. Berenger

    Liquid Pump Blocked Outlet Sizing Flow Criteria

    Hi, I am sizing relief valves for liquid system for the first time. I usually work with natural gas. I know the code/standard and the equations and I can calculate orifice sizes. However, I do have a question regarding blocked outlet on a pump. The facility is a pump station with 18 inch...
  12. Berenger

    Pipeline System Relief Scenarios

    Hi all, I am working on a crude pipeline transporting around 3000 barrels/hour of crude. I have done the system relief analysis, but have a few of questions: Is blocked outlet a credible scenario? Especially at pump discharges? If not, why? Finally, if sizing blocked discharge on a pump, do...
  13. Berenger

    Sump Siting and Design

    Hi, Can anyone help me with how to size a sump? I have searched extensively for this and the only things that come up have to do with aquariums and aquatics. So, how do I size a sump? What volumes do I use? Low level of all the vessels? Also, how do you decide between an open or closed...
  14. Berenger

    Low Pressure Vessel Pressure Protection

    Hi everyone, We are installing a new low pressure 2-phase separator in the field. The operating P is around 120 psig. The pipeline and the vessel are to 1375 psig @ 185 F. I had a discussion with another engineer on how best to protect this vessel. His point is that since the operating P is...
  15. Berenger

    Fractionation Train Design And Operation

    Hi all, I am designing a fractionation train to recover ethane, propane and butanes. Can anyone help me with typical condenser pressures and temperatures? Also, I have substantial methane in the deethanizer distillate stream that I would like to remove to get pure ethane. Can anyone help me...
  16. Berenger

    TEG As A Heat Transfer Medium

    I recently came across a P&ID that shows a shell and tube heat exchanger. In addition to increasing the temperature of the natural gas with the steam, the P&ID shows TEG going into the exchanger as a heat transfer fluid. Does anyone have a practical knowledge of how this process work? Not how...
  17. Berenger

    Valve Coefficient for a Back Pressure Valve

    Thanks, LittleItch, for your help. No, you did not insult me...I was just trying to explain the extent of my understanding of the issue. That's what the forum is about - helping others, and you did just that. It's quite clear to me now. I really appreciate your assistance.
  18. Berenger

    Valve Coefficient for a Back Pressure Valve

    Sorry, forgot the file.http://files.engineering.com/getfile.aspx?folder=2651a0a9-b355-41e2-b7e2-653a4d7ae65f&file=12321.JPG
  19. Berenger

    Valve Coefficient for a Back Pressure Valve

    LittleInch, I think I have quite a good grasp on regulator operations and design equations. I am still a little confused on what the pressure drop will be in some situations (such as when the regulator is a last layer of protection and is not expected to be activated). I have included a scenario...
  20. Berenger

    Valve Coefficient for a Back Pressure Valve

    Thanks, LittleInch, for the help. By the way, i'd rather send this to a valve engineer. But, for some reason, the senior engineer wants it done in-house. We've always sent control valves and regulators out to be sized.
Back
Top