Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: ThorA
  • Order by date
  1. ThorA

    Custom symbol font locking

    Make sure that your setting is as shown here: Use definition is the trick! NX10 Ansys 16.2 HP Z820 / Quadro4000
  2. ThorA

    Mechanical geometry "tolerance"

    Hi, If you mean pre-processor as NX, it is not polygonal, it is circular in NX before I import it. As far as I know there are no controls in the geometry Interface of NX-Ansys. Geometry in NX is still graphically polygonal, but much nicer: Ansys understands that this is circular in the...
  3. ThorA

    Mechanical geometry "tolerance"

    Hi, We have many large circular components that we import from Siemens NX. No Ansys geometry modeller. In some cases it becomes very difficult to select graphics and is quite an annoyance that the geometry is very coarse. The circular edges are not circular at all but an n-sided polygon, where...
  4. ThorA

    NX Journal Question - Update Weight Data Now

    Hi, This code updates the mass of the work part: ' NX 10.0.1.4 ' Journal created by jevtho04 on Fri Jul 10 21:49:42 2015 Romance Daylight Time ' Option Strict Off Imports System Imports NXOpen Module NXJournal Sub Main (ByVal args() As String) Dim theSession As NXOpen.Session =...
  5. ThorA

    Teamcenter 4Tier Users

    Hi, We have from 40 to 60 ms ping to our web-tier server. Our volume server is at a remote location so we also have 40 to 60 ms ping to volume server. At the moment is the performance not good. NX8.0.3.4 TC 9.1.2.3. HP Z820 / QuadroK4000
  6. ThorA

    Centrelines & Broken Views

    You could also add the centerline to an expanded view. Just remember to scale your centerline. NX8.0.3.4 TC 9.1.2.3. HP Z820 / QuadroK4000
  7. ThorA

    Custom Symbol Creation

    Thanks! That was the trick! This behaviour then has changed from NX6. NX8.0.3.4 TC 9.1.2.3. HP Z820 / QuadroK4000
  8. ThorA

    Custom Symbol Creation

    Hi, We have the exact same problem on our native setup. NX8.0.3.4 MP8. Have also tried many different folders local and on a network drive. It is the same for all users on our site. NX8.0.3.4 TC 9.1.2.3. HP Z820 / QuadroK4000
  9. ThorA

    Switch Part tool

    Dear CNSZU Thanks for the prompt response. 1. It happens for all displayed parts in NX Managed. It works in a native assembly. I suppose the error is somewhere in our TC config. start expand cNXSwitchPart.CycleIndex1: -1 cNXSwitchPart.DisplayPartPathList.Count: 0 cNXSwitchPart.CycleIndex2: 0...
  10. ThorA

    Switch Part tool

    Dear CNSZU. First of all. Congratulations on the tool! It is superb! Version 1.3 seems to have 2 bugs for us. 1. Some issue when pressing the expand to displayed part: Full error message See the end of this message for details on invoking just-in-time (JIT) debugging instead of this...
Back
Top