Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. virata

    Pump Mechanical Seal: Single Seal vs Double Seal for Toxic Process Fluid

    Thanks guys. I will coordinate with tech people and see what I can do. RVAmeche - We currently looking at API 610 pumps only.
  2. virata

    Pump Mechanical Seal: Single Seal vs Double Seal for Toxic Process Fluid

    Hi guys, When the process fluid is specified as TOXIC in the data sheet, it is required to use Dual Mechanical Seals? Could you explain the degree of toxicity of the process fluid for it to require dual seals rather than just a single seal. Currently I am working on data sheets where it...
  3. virata

    API Plan 23 Cooling Water Requirements

    Hi guys, In Plan 23, who normally dictates the cooling water requirements such flow, temp, pressure. Is it the supplier or is there also a section on API 682 where it dictates the CW requirements? Thanks, Virata
  4. virata

    Why is NPSH can not be determined if the suction is flooded (?)

    Hi Artisi, it's available. But I would like to also know if this is also the situation with required. Regards, Virata
  5. virata

    Why is NPSH can not be determined if the suction is flooded (?)

    Dear everyone, I want to consult you guys on this. I asked a package vendor (for a chemical injection package) to provide me both Differential Pressure and NPSH for the metering pump. However, the vendor says this is not required because the suction is flooded. See below: For the differential...
  6. virata

    How to replace Pump impeller - ClydeUnion Centrifugal Pump

    Hello there, Does anyone of you have an IOM of a Clyde Union OH centrifugal pump? Here is the pump model:SPXFLOW Clyde Union 3 x 4 x 16B pumps. We are needing this to look into how the impeller is being replaced at site. Thus, the disassembly and assembly notes from the IOM would greatly help...
  7. virata

    PUMP & INSTRUMENTS ON HAZARDOUS AREA

    Thank you LittleInch and bimr!
  8. virata

    PUMP & INSTRUMENTS ON HAZARDOUS AREA

    Hi guys, I have an ATEX-rated air operated double diaphragm pump including the air filter regulator and PSV. On the area classification plot plan, it is shown that it is under Cl 1, Div 2. My AODD is fine I believe since it is ATEX rated already. How about the instruments included in this...
  9. virata

    HIGHER SERVICE FACTOR OF A MOTOR

    All, I understand the concern on overloads and all that. The vendor had actually sized the motor large enough to not get in to the service factor. I just want to add that our project spec says that at 1.0hp and up the SF shall be 1.15. And what i just wanted to know if the SF of 1.25 is...
  10. virata

    HIGHER SERVICE FACTOR OF A MOTOR

    Thank you Warros. Dave, no overloads here I believe.
  11. virata

    HIGHER SERVICE FACTOR OF A MOTOR

    Hi guys, I'd like to know what is the impact of having a 100-hp motor of 1.25 service factor. In our motor data sheet it is 1.15 SF. Is 1.25 SF safe to use and acceptable? Kindly let me know your thoughts. Thanks, V.
  12. virata

    PUMP MODEL

    Hey guys, Are there any AODD pump models that can comply to a maximum suction pressure of 150psig (this is due the pump is designed to a design to the maximum pressure of the source vessel. Some pump vendor can only limit there max suction pressure to 5 psig. Also, are there any options to...
  13. virata

    VESSEL SIZING - RETENTION TIME

    Hello Dinesh, Compressor is Oil-lubricated screw compressor and is operated by Load/Unload controls(or Auto Dual Control). The vendor actually did assume that the beginning pressure is the same value of the outlet of the compressor discharge and air dryer discharge (dryer in the package), is...
  14. virata

    VESSEL SIZING - RETENTION TIME

    Hello guys, I have a question regarding Vessel sizing (an Air Receiver within Air Compressor Package). The vendor got back to us and said that they need to know three things: 1) Retention time 2) Beginning Pressure 3) Ending pressure at the end of retention time (and also flow at this period)...
  15. virata

    REQUIRED WINTERIZATION FOR PUMP

    Thank you so much guys, I'll get back to you if I get some questions again. Regards, V
  16. virata

    REQUIRED WINTERIZATION FOR PUMP

    Thank you guys for your reply, LitteInch --- I meant the (2). Referring to P&ID this AODD will be installed outdoor ( i don;t know yet if location will change though). It will be installed in OHIO and it will be pumping condensate (mixture of water or hydrocarbon). I don't understand why we...
  17. virata

    REQUIRED WINTERIZATION FOR PUMP

    Hello guys, I have a question, how do vendor winterize a pump? This pump is an AODD pump. Thank you and hope to get some response from you. Regards, Virata
  18. virata

    Specific Speed Limit Issue

    Here is the Pump curve. The alternate (with lower Nss) pump has lower effiency.http://files.engineering.com/getfile.aspx?folder=43d2d561-44e4-4c19-a879-b7a160d8c388&file=Nss.pdf
Back
Top