  1. coolniks37

    Drilling after hydrotest B31.3

    Thanks SnTMan, and LittleInch for your replies. Could you point me to ASME B31.3 clause which lists activities that can be carried out post hydro?
  2. coolniks37

    Drilling after hydrotest B31.3

    Exactly. My design pressure is around 20psi, and actual operating might be less than that. Is there an option to hydrotest header in undrilled condition, and later drill on site. If some welding is needed at site, can it be done at site without PWHT & hydro?
  3. coolniks37

    Welding lap joint stub end ASME B31.3

    Perfect! Appreciate your help! Thanks a lot, LittleInch.
  4. coolniks37

    Drilling after hydrotest B31.3

    Thanks again! Though it is open, wouldnt it be subjected to gas pressure during operation. Again, in B31.3 when code says about hydrotest has to be carried out to check tightness - whether it is for checking leakage of joints or integrity of the wall ?
  5. coolniks37

    Welding lap joint stub end ASME B31.3

    Hi LittleInch, Thanks a lot! Seems we are on the same page. Reason for Lap Jt flanges, is that piping is Ti & no Ti flanges listed in B16.5.
  6. coolniks37

    Welding lap joint stub end ASME B31.3

    I have a short section of piping that needs to connect two flanged valves. Because of space constraints, I am planning to weld two stub ends together.. Is that allowed per ASME B31.3? https://files.engineering.com/getfile.aspx?folder=b2722345-8dc1-47a7-b44b-603a32100df4&file=Stubend.PNG
  7. coolniks37

    Drilling after hydrotest B31.3

    Thank you @LittleInch for your response. I am actually designing the section with all holes. Is it possible to get an exception to hydrotest, as the section is open to atmosphere as per 345.1.d ?
  8. coolniks37

    Drilling after hydrotest B31.3

    Hi all, I am designing a gas header for a ground flare. Applicable code of design is B31.3 & hydrotest will need to be conducted. Is there an option in B31.3 to hydrotest the header in undrilled condition and later after hydrotest drill the distribution holes? Thanks in advance!
  9. coolniks37

    Exception to hydrotest

    Hi all, I am designing a gas distribution header, for a flare, with numerous holes connected to burners. System operates around 20psi. Can i take exception to hydrotest under B31.3 - 345.1 (d) as system is open to atmosphere. There are valves upstream to isolate the burners. I need to install...
  10. coolniks37

    Gasket dimensions for Wafer type check valve and butterfly valve

    Thanks again mk3223 & akpipelineengr for your comments. Considering the recommendation for a gasket by the valve supplier, I'm leaning towards a full face gasket on expansion joint end and a ring gasket on the other. Any concerns or alternative suggestions on this approach?
  11. coolniks37

    Gasket dimensions for Wafer type check valve and butterfly valve

    Thanks mk3223 & akpipelineengr. Pls find attached a snip of the arrangement. I am trying to finalize the gasket dimensions at both end of the valve.
  12. coolniks37

    Gasket dimensions for Wafer type check valve and butterfly valve

    Thanks @akpipelineengr. The valve sits inside the bolt circle of the flange. The only issue here is that, the valve is flat face & has a raised face flange connection on one end & flat face expansion jt on the other end.
  13. coolniks37

    Gasket dimensions for Wafer type check valve and butterfly valve

    Hey everyone, Need some advice on gasket dimensions for a 12" wafer-style butterfly valve connecting to a 12" B16.5 flat face flange. It's for an air line from a 10psi blower. Any insights on the ideal dimensions? Also, what adjustments are needed if I switch to an RF flange? Similarly, facing...
  14. coolniks37

    Gasket dimension of wafer valve

    Hi LittleInch, The medium handled is corrosive. I want to avoid crevice corrosion from happening.
  15. coolniks37

    Gasket dimension of wafer valve

    Thanks a lot @TugboatEng. I am seeing that the ID of the valve is quite smaller than the ID of the standard ring gasket. Will that pose any issue?
  16. coolniks37

    Gasket dimension of wafer valve

    Hi I am connecting a 12" wafer check valve with a 12" ANSI 150 RF flange. I need to use a custom gasket between these. How do I determine the dimensions of the gasket?
  17. coolniks37

    NFPA 54 - Pressure Testing

    Hi all, I am constructing a fuel gas line (25psi) and confused with pressure testing of pipe. Can I do shop hydrotest instead of pressure testing and assemble the parts at site? NFPA 54 Cl 8.1.2 (given below) doesn't mention hydrotest. "Test Medium. The test medium shall be air, nitrogen...
  18. coolniks37

    A36 equivalent pipe specification

    Thanks @PhamENG & @MotorCity.. I meant pipes for transporting liquid. I need to run a piping from Customer end to my equipment. Customer says his piping is A36. Can I use SA106GrB pipe? Are they similar in chemical composition?
  19. coolniks37

    A36 equivalent pipe specification

    Is there any piping specification equivalent to A36?
  20. coolniks37

    Secondary steam separator inside nuclear steam generator

    Hi What care to be taken while installing secondary steam separator (vane type inside box) in SG? Whether arc strike / spatter allowed on vane elements? What are the possible damages in operation ? Any literature would immensely help. Thanks in advance