Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. braham0793

    END - Anchor bolt

    Potosí, Bolivia. The information that I have been able to gather up to now is the following: Apparently they used the bolts as supports to assemble the last tank ring. The shoring was done with tubular wire E71T-1. If I have more information, I will inform you as soon as possible. Thank you!
  2. braham0793

    exterior / bottom flange and helmet

    Dear, Good morning; I would like to know the tolerance in millimeters between the separation of the bottom of the tank with the cemented base and of being outside the tolerance which is the correct correction process. Example.- Template of the tab through the use of 20 lb. rope. The tank is...
  3. braham0793

    END - Anchor bolt

    Dear; Good morning, I have detected that the anchor bolts in a storage tank (API 650), are propped up (see image) the supervisor in charge has indicated to me that this has been done by constructive process. Well I assume it is the first time that this contractor makes this type of assembly...
  4. braham0793

    Welded-bolted joint?

    Dear; Good afternoon, I am assembling a storage ship and in the approved plans for construction I have the following connection detail in the union beam-beam: The board is bolted but my client tells me that we solder that board, I have consulted my technical office but they still do not...
  5. braham0793

    Deformed beam

    1.- The column was not designed correctly. 2.- The supporting load is "small". In conclusion after straightening I will reinforce it.
  6. braham0793

    Deformed beam

    The appearance of the structure is due to the deposition of paint and over time have formed "protective layers" that appear to have rid the steel of the oxidation. The entire structure works as a "paint booth".
  7. braham0793

    Deformed beam

    Dear ; Good afternoon, A client has asked me to reinforce 4 ships, I am doing the relevant reviews and I have found the following surprise: The beam that works as a column has been deformed. According to what my client indicates is because they had problems when mounting the roof and...
  8. braham0793

    ANSI 818.2.2 / ASME B18.2.2

    What is the difference between ANSI 818.2.2 and ASME B18.2.2
  9. braham0793

    Bolts for "feedwell" - thickener

    Thank you very much for your answer.
  10. braham0793

    Bolts for "feedwell" - thickener

    Dear; Good morning, I wonder if I replace a millimetric nut "ASTM A563M" class 10S by millimeter nut "ASTM A194M 2H". In case you can not make the change that equivalent could replace it? Consider the bolt is Millimeter "ASTM A325M-1" and be supplied galvanized. Thank you very much for...
  11. braham0793

    Equivalent ASTM A563M, class 10S

    Dear; Good morning, I wonder if I replace a millimetric nut "ASTM A563M" class 10S by millimeter nut "ASTM A194M 2H". In case you can not make the change that equivalent could replace it? Consider the bolt is Millimeter "ASTM A325M-1" and be supplied galvanized. Thank you very much for...
  12. braham0793

    countersunk bolts - Standard

    It is 83 ° to be exact.
  13. braham0793

    countersunk bolts - Standard

    Dear; Good Morning, Someone who can tell me the American standard for countersunk bolts? Best regards.
  14. braham0793

    victaulic Accessories

    Dear; Good afternoon, There is a difference between VICTAULIC accessories brand with other brands?. Since eh observed that the Victaulic brand, have a higher cost. Best regards.
  15. braham0793

    Victaulic pipe - grooved joints.

    Dear; Good morning, I was reviewing the plans for my client and found that there eh grooved boards where not specify what type of coupling victaulic must carry. I would like to know what conditions must meet the line to install flexible or rigid coupling victaulic. Greetings.
  16. braham0793

    grooved pipe

    Dear; I require support for interpreting the following: - GROOVED ENDS 6MM RUBBER LINED For example: - PIPE ERW SCH 40 CS A53-B GROOVED ENDS 6MM RUBBER LINED Thanks for your support
  17. braham0793

    Galvanized pipe cleaning

    Dear; Good morning, I have received galvanized pipe work with dirt on the outside of the tube I wonder if they know of any solution to clean the tubes because dirt is relatively low. PS: Mainly spots are indelible marker, earth.
  18. braham0793

    Inox / Monel

    Sorry, the line is 2 ".
  19. braham0793

    Inox / Monel

    Dear ; Good afternoon, I will make a line of stainless / Monel 400 pipe, I wonder what suggestions may indicate me to bring good manufacturing process, welding and cleaning. The line is 3 "and the seals are SW. The manufacture is for a hydrogen plant. Best regards.
  20. braham0793

    ALTERNATE MATERIAL REQUIREMENT FOR A234 WP11

    The thickness of the fixture is to be reduced by 9 mm, it is too in my opinion not risk the line to place said accessory designer see if you can make a graft tube 14 ". Otherwise quoted by a tee in sch-160 which is more commercial.
Back
Top