Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. 142846

    Auto cad

    Hello every body I have a lot of .dwg colored files. Is there any way to convert these dwg files to dwg black layer files. In the other hand i want to have one color (black) drawing not colored. I should say that i can convert one by one but i can not convert batch (for example 2000...
  2. 142846

    convert dwg file to searchable pdf

    Autodesk Autocad 2018 windows 10
  3. 142846

    convert dwg file to searchable pdf

    you are right. thanks for your perfect attention and sorry (espacially from 3DDave) for any misunderastanding. I will try improve my english.
  4. 142846

    convert dwg file to searchable pdf

    shame for what!? or for who!? From Words to Do the distance is hundreds kilometers. Had you tried that yourself?
  5. 142846

    convert dwg file to searchable pdf

    I couldn't find any useful subject in this adress.
  6. 142846

    convert dwg file to searchable pdf

    Hello, I did Your solution, but the output is a nonsearchable pdf file. my question is: Is there any way where we can convert the Autocad DWG file to searchable PDF without Autocad SHX Text? thanks
  7. 142846

    convert dwg file to searchable pdf

    I am not good on cad. Is it possible say how can I do this setting. best regards.
  8. 142846

    convert dwg file to searchable pdf

    unfortunately autocad default settings dose not produce a searchable PDF. I tryed some settings/Options in the printer setup and could not have searchble pdf. for this reason I raised this question. only pdf to dwg.pc3 produce searchable pdf, but cad text are in the comments of pdf files.
  9. 142846

    convert dwg file to searchable pdf

    I need searchable pdf file because for example I want to know how many "psv" text is in the one pdf file.
  10. 142846

    convert dwg file to searchable pdf

    How to convert dwg file to searchable pdf file? thanks for any respond
  11. 142846

    wellhead Shut-in pressure

    There is not any water/gas injection or gas lift or ESP pump in the site. There is not any water/gas injection or gas lift or ESP pump in the site. Dear friends Basically I need the wellhead Shut-in pressure value to design and determine the maximum allowable working pressure of the flow...
  12. 142846

    wellhead Shut-in pressure

    dear petroleum I agree with your point of view but the subsuface engineer says because of probability change of reservoir conditions in future, the actual wellhead shut-in pressure is grather than 1200 psig and is almost 1500 psig (based on their calculations). my question is: Is it possible...
  13. 142846

    wellhead Shut-in pressure

    How does wellhead Shut-in pressure could be determined? The pressure gauge installed on the X-Tree has been reached to 1200 psig after a long period when the X-Tree output valve is close and there is not any flow from the well. Can we say that the wellhead shut-in pressure is 1200 psig or for...
  14. 142846

    STEADY STATE STEADY FLOW (SSSF) PROCESS

    In thermodynamic there is an important issue "STEADY STATE STEADY FLOW (SSSF) PROCESS". MY QUESTION IS: Is there any steady flow process that is not steady state? or is there any steady state process that is not steady flow? what is the difference between steady state and steady flow process...
  15. 142846

    vibration sensor for stop the pump or compressor

    dear friends below is paragraph A.8.2.2.4 page 67 of API rp 14c about the pumps: As you can see, regardless of pump type or manufacturer or purchaser or bidder or company or EPCC or any limitation (just pump power), API rp 14c clearly says vibration sensor should be used for pumps with driver...
  16. 142846

    vibration sensor for stop the pump or compressor

    dear friends you know that vibration safety sensor is used to shut off pump or compressors when the vibration is high. considering (not real) I want to buy all 4 following pumps or compressors with vibration switch: 1. 20 kw 2. 500 kw 3. 1000 kw 4. 1500 kw in your opinion for which of the...
  17. 142846

    application of pressure vessel in vacuum service

    thank you every body . based on your comments, I understood the vacuum vessels has own calculations. Just to better understanding the subject (me), imagine the design pressure was 100 barg instead of 10 barg (we don't have this vessel and just imagine if we had) , what was your answer in this...
  18. 142846

    vibration sensor for stop the pump or compressor

    Hello every body In oil and gas industry, some huge pumps or compressors is equipped with vibration switch to shut down the pump or compressors and others have not vibration switch. It seems for huge pumps or compressors the installation a vibration switch is mandatory. My question is what is...
  19. 142846

    application of pressure vessel in vacuum service

    hello every body In the oil and gas company there is a pressure vessel with name plate that shows the specification as follow: design pressure (MAWP): 10 barg design temperature: 100 C length: 8 meter I.D = 2.5 meter material; carbon steel and there is not any information about vacuum design...
  20. 142846

    LIST OF API STANDARD

    JStephen (Mechanical. Thanks a lot. Very useful.