  1. WattsNew

    How do I calculate voltage drop in a 400Hz system?

    hgldr...please share the information irrespective if you dont mind. I am interested in looking at it. thanks. :)
  2. WattsNew

    How do I calculate voltage drop in a 400Hz system?

    Alternatively you can utilize software for power flow like ETAP. Change the project frequency to 400 Hz and when you select 50/60Hz cables from the library, ETAP automatically calculates the new impedance based on 400 Hz. I have seen this application used for shipboard power systems.
  3. WattsNew

    DC Drive Harmonics - simulation

    Hi Tony, I have done some harmonic simulation in ETAP using VFD's and tested the programs capability of modeling upto 36 pulse VFD using 6 pulse drives. It is fairly simple. I can email you a screen capture of what the circuit would look like for 12,18,24,30 and 36 pulse drives along with the...
  4. WattsNew

    Synchronous Motor Starting

    Thanks gordon. My email address is apogee1977@hotmail.com
  5. WattsNew

    Synchronous Motor Starting

    gordonl, Thanks for your input. I am aware of the behavior of sync motor startup. I am looking for actual test data for any size synchronous motor with any characteristic. I need this for my research.
  6. WattsNew

    Synchronous Motor Starting

    Does anyone have test data or reference that shows plots for synchronous motor starting (using a discharge resistance and then applying the excitation? Thanks in advance
  7. WattsNew

    Generator Negative Sequence Protection

    Does any one know how to calculate generator I2^2 t curve for coordination purposes? I know that K varies between 2 - 40 and I2 is percent of stator FLA. What percent of FLA is used to draw the curve? Hope the question makes sense. Thanks in advance
  8. WattsNew

    Relay Secondary Injection Unit

    I read HiSets comments and the ETAP ARTTS works with a laptop computer and can test almost 24 different IEEE types of relays. Quite lightweight too, weighs in about 18 kgs.
  9. WattsNew

    Relay Secondary Injection Unit

    Hi Deansharafi Omicron and Doble are very expensive. You might want to look at ETAP ARTTS which is a secondary injection test set I have used and works real well because it allows upto 9 CT inputs and interfaces with the ETAP coordination program. The best thing is service is available in the...
  10. WattsNew

    Analyzing Power Plant Operating Data

    You can refer to www.etap.com/psms for analyzing electrical operating data. I am not sure if vibration data is handled by them also?
  11. WattsNew

    GROUNDING CALCULATION

    You might want to use standard softwares like ETAP that comply with IEEE 80-2000 to save you a lot of iteration time. Knowledge of 3Io LG fault current and X/R ratio is required.
  12. WattsNew

    X/R transformer calculations

    What is the nameplate kVA of the transformer? ETAP actually has typical %Z and X/R values for any nameplate transformer. I can get you the values from there.
  13. WattsNew

    Ground Grid Analysis

    I have used ETAP on a number of projects. It is fairly simple to use and offers IEEE and FEM Methods. www.etap.com
  14. WattsNew

    Moving Train Analysis

    Hi jbartos, Thanks for the links. I will have to scan through the softwares mentioned. Essentially what I am looking for is a way to model the electrical network for a transit system and then simulate acceleration / deacceleration of trains based upon their schedule. Thanks
  15. WattsNew

    Moving Train Analysis

    Hello All, Does anyone know of a Standard which talks about Moving Train Analysis or a software that does it? Thanks in advance
  16. WattsNew

    Capacitor Bank Protection

    Sett. I am doing the same thing at this point. IEEE C37.99-1990 "IEEE Guide for the Protection of shunt Capacitor Banks" has some good information but nothign related to the rupture characteristics. Search continues. Thanks.
  17. WattsNew

    Capacitor Bank Protection

    Capacitor banks utilize group fusing. The fuse should have a time-current clearing charactersitic that lies below the time current case rupture probability characteristic of the capcitor units. THere are 4 zones defined by 3 such curves - Safe Zone, Zone 1, Zone 2 and Hazardous Zone. Finally...
  18. WattsNew

    Load Shedding & Mangement Specification

    Check this one out http://www.etap.com/psms_ils.htm
  19. WattsNew

    Harmonic Calculation

    You can also use a software analysis tool like ETAP to perform harmonic analysis. It can also run a custom frequency scan.
  20. WattsNew

    Electrical Short Circuit Sotware?

    What DanDel said. ETAP is also Nuclear certified. It is a quick stop shop for all modules needs for industrial and distribution systems. Pricing is actually competitive.