  1. ZapSib

    Time interval for measuring transients in SCADA

    COMTRADE is the standard ( refer to IEC 60255-24) so that transient record use common format. => https://webstore.iec.ch/publication/1170
  2. ZapSib

    Time interval for measuring transients in SCADA

    Hi, Are yours relays, IED ( i.e. numerical) ? In this case, the best way forward to get use the relays records ( i.e. COMTRADE) for further analysis. such records samples at ( typical values) 20 to 50 samples /cycle. the outstanding issue will be whether you will be able to (automatiquely)...
  3. ZapSib

    Transformer Diff Protection Problem during the TF Energization

    Thanks for sharing the files. I also replied to you on linkedin, please check.
  4. ZapSib

    Transformer Diff Protection Problem during the TF Energization

    I suggest you put your settings/DR etc .. on e.g. DROPBOX ( or equivalent) and share here the link.
  5. ZapSib

    Differential Current Fault on generator multi differential relay protection

    What happened when 87G operated ? did you energized a power transformer or similar beast ? Did the relay recorded a COMTRADE file ?
  6. ZapSib

    MTBF of Protection Relays and other things

    I attached ( or at least hope I have) a pdf file describing the MTBF stuff. http://files.engineering.com/getfile.aspx?folder=12b569bd-a93e-49f3-bb3e-952630c1369f&file=Stats.pdf Based on my experience, unavailability of IED is a matter of minutes, not days! the last figures from Schneider...
  7. ZapSib

    Line tripping on transformer inrush

    Some distance protection are available with inrush restraint ( e.g. http://www.schneider-electric.com/download/ww/en/results/0/0/19071615-MiCOM-P44x-current/0/). That being said, is it the inrush itself causing the maloperation ? Did you check if the CT goes onto saturation ( due to long DC...
  8. ZapSib

    MiCOM Px3x Redundand Network - Signals time stamp in Local SCADA IEC 61850

    Pscheshki, Please log your request as Poland (Poland is supra-regional center with former Areva, now SCHNEIDER office) and shall help you. Aside note, did you prove your Rg switches ? REGARDS.
  9. ZapSib

    MiCOM Px3x Redundand Network - Signals time stamp in Local SCADA IEC 61850

    Hello, I would suggest you contact Schneider Electric support at below link : http://www2.schneider-electric.com/sites/corporate/en/support/contact/customer-care-contact.page If your country is not listed, let me know where you are located. Regards.
  10. ZapSib

    AEG SD14E Distance Protection Relay

    Hi Neil, I suggest you contact Schneider Electric in Germany, they took over heritage from AEG. Regards.
  11. ZapSib

    UNRISTRICTED EARTH FAULT MICOM P120

    For MiCOM P120, as all so-said P20 range, setting is made related to In ( e.g. 0.1 In for 10% threshold). For information, MiCOM P120 ( as well as other MiCOM) belongs now to Schneider Electric.
  12. ZapSib

    Current transformers transient behaviour

    Thanks Dave for your suggestion.
  13. ZapSib

    Current transformers transient behaviour

    Hello, I am looking for the following article but was not able to locate it. Does anyone knows where can I get it ? Author is N.E. Korponay and title is " the transient behaviour and use of current transformers". It comes from brown bovery review, 1975. Thanks in advance.
  14. ZapSib

    MICOM P542 Secondary Injection

    Hi Bdf, the trip itself will not be latched but the output contact ( RLxx, blue color in PSL) shall be latched. On the remote end, received signal shall be routed to RL, this one being latched. regards,
  15. ZapSib

    CT accuracy

    Limits at nominal current for 5P/10P are given in IEC 60044-1. this one is being replaced, but I assume it is still given in the new norm.( sorry, I don't remenber numbering).
  16. ZapSib

    Gen./Transformer Differential Prot.

    P34x may be use as block protection as well ...
  17. ZapSib

    MICOM P923 RELAY

    Hello, did you have a look at the disturbance record?
  18. ZapSib

    Diesel generator differential protection trip help

    Scott, Is there anythink happening in th esirrounding network when 87T trip ? I mean, is there any Tfo or Capacitor bank switched in ?
  19. ZapSib

    areva DCS

    I belive that most of automation buissness belong now to Schneider Electric. Actually only Micom Px4x are shared betwwen both company and all other range belongs to Schneider Electric only. Is it quite new from SE people but they should be able to support you anyhow.
  20. ZapSib

    Generator protection : Loss Of Field

    Thank you David. I will refer to Blackburn when back in Office. Is such kind of drawing usual in US ? Regards.