  1. Drexl

    Code for Full-Port Ball Valve

    EN 1983 (it is table 4 in the 2006 issue)
  2. Drexl

    Difference in DN size and actual bore in ball valve

    EN 1983 specifies the minimun diameter of ball valves per DN-size/pressure class. The listed valves are all full bore.
  3. Drexl

    Would this Valve Move?

    It will move until the forces equalize.
  4. Drexl

    Need to calculate pressure increase from heating water going through a pipe that is open

    I can't really think of what kind of application this would be, are you sure you describe it correctly? In your example, if you have 120C at the outlet (at atmospheric pressure at equilibrium) you must have pure steam and it is not possible to supply that much heat through such a short pipe. If...
  5. Drexl

    EN 13444-3 vs EN 286-1

    As XL83NL says EN 13445 is harmonized to PED and used for unfired pressure vessels. EN 286 is harmonized with SPVD and used for simple unfired pressure vessels. It covers smaller unalloyed steel and aluminium vessels with a pressure of max 30 bar for air and nitrogen. The exact scope of the...
  6. Drexl

    Tube side design temperature

    As I remember the standards state that calculation has to be done on the higher of the tube/shell side temperature unless a lower temperature can be justified. If you proteect the tubeside using a switch as golpesar88 suggests, this switch is a protection function of a pressure vessel and has to...
  7. Drexl

    Pressure drop - low quality steam at low pressures

    I see I was a bit unclear in my post. There is of course steam exhaust pipe and a liquid drain pipe. During normally occurring operating cases sufficient separation will take place. It is however possible to have all valves draining to the tank simultaneously giving extreme flow to the tank. The...
  8. Drexl

    PSV outlet piping to atmosphere design pressure?

    Calculate the pressure drop in the outlet pipe and there you have your maximum pressure. Select design pressure accordingly.
  9. Drexl

    Pressure drop - low quality steam at low pressures

    Latexman, thanks. I will review this. There is quite a lot of literature similar to this that investigate mass flows from pipe breaks connected to the pressure vessel of nuclear reactors. The problem is that they have high pressure and usually saturated liquid at inlet. The translation to my...
  10. Drexl

    Pressure drop - low quality steam at low pressures

    Hi, I was wondering if anyone know a proper pressure drop correlation for 1. Low quality steam x=0.1-0.3 2. Low pressure 0.2-1.5 bar(a) I have a flash tank connected to the condenser by a short pipe. At a disturbance case I expect extreme flow to the tank and would like to calculate what the...
  11. Drexl

    Outlet temperature of HE at higher inlet temp.

    Hi, If your problem is selection of design temperature, have you considered that the fan might trip and you blow 200°C through the heat exchanger?
  12. Drexl

    Manual Valve Management System

    I didn't even know there were plants where you don't number your equipment :) I don't see how numbering the valves can be much more work than painting them. That is the first key to having proper operating instructions.
  13. Drexl

    Power plant water chemistry literature

    Hi, I'm looking for comprehensive and modern literature on power plant water chemistry. Anyone have any suggestions? What i'm looking for: -History/evolution of water treatment -Used treatment programs -Used chemicals -Description of mechanisms - stress corrosion cracking, FAC, pitting, erosion...
  14. Drexl

    Relief Valve Exhaust Piping for different operating pressure lines

    Generally you can combine outlet, see for example EN 764-7 ch 8.2.3. It shall be shown that the back-pressure doesn't prevent the operation of the safety valves as described in previous posts. The conservative and often correct way to size the outlet is then to assume that all valves are...
  15. Drexl

    Alter exisitng heat exchanger conditions

    UAF = const is a reasonable assumption in many cases where changes are not so big and highest accuracy is not required. However the next step would be to adjust U for changes in flow velocity, assuming this is your biggest change. If you try calculating the heat transfer coefficient on both...
  16. Drexl

    Estimation of air inlekkage rate through a leak at the seal of vacuum centrifugal pump

    Are you saying you have a hole with atmospheric pressure on one side and 20 mbara on the other side. If so estimate the area of the orifice and use the methods described in amongst other Crane or Perry. No time to describe in detail atm but you can show your calculations for comment if you want.
  17. Drexl

    Steam turbine - sudden temperature change

    Hi, I'm looking at having two boilers connected in parallel that are delivering steam at different temperatures. If one of the boilers trip, I get a sudden drop in mass flow and a sudden change in temperature of the live steam. Would any turbine specialist be so kind to give some guiding values...