Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. NutAce

    E-Bom in NX

    Hi Tomas Thanks for you answer. I realize there is no option to auto balloon without having a parts list on the drawing. Placing the partlist outside the drawing frame (if you don't want that on the drawing) is the only solution for that. But I think you misunderstood my question. I want to...
  2. NutAce

    E-Bom in NX

    Hello folks. It's been a while since I have visited this forum. I have a question about Engineering BOM's We (Company I work for) Is just now starting to use the Design and Engineering BOM in Siemens Teamcenter. In our opinion (we might completely misunderstand this) it should be possible to...
  3. NutAce

    Searching In Teamcenter

    Hi Teamcenter doesn't care about folders. All data is just one big heap for Teamcenter. Therefor there are no o.o.t.b Queries in Teamcenter to search within a specific folder (the exception would be the users Home Folder) Easiest would be, to create an SQL query on the DB directly and make that...
  4. NutAce

    NX1892 : Attempt to save bad pointer error

    Try the Part Cleanup utility. This usually helps when we encounter this. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11
  5. NutAce

    Weight and Mass Information - NX12

    Are they all in the same Assembly? You first need to make sure, in the properties of each component, that the "Update Data on Save" is checked. Then you can see, in your assembly, the total weight of your structure. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel...
  6. NutAce

    NC files for NX

    As you can see from the answers above, yes it is possible. You just need all the licenses for the different CAM modules in NX. And the correct postprocessors of course. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from...
  7. NutAce

    NX .prt file shows different

    Hold down Shift key while you right click on it. Then select "open With", choose "select another app", and make the setting to use this always. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11
  8. NutAce

    Time difference in saving when using OOTB Save and Save Work Part only

    The Time difference between the two will depend on how many parts are loaded and considered modified by NX The "Save" action saves all modified parts in your displayed Assembly (or Drawing). The "save workpart only"...well the name says it all. :) If you do a "Save" action with only a single...
  9. NutAce

    Are there any characters in Naming conventions we must avoid for parts in Teamcenter

    If you have a good Teamcenter Administrator in your company, he/she will have configured Teamcenter in such a way that special Characters aren't even allowed. Apparently, the company where Toost is working doesn't have this configured. ;) Ronald van den Broek Senior Application Engineer...
  10. NutAce

    Radius Flip Issue

    Hi Defining radii in sketches is bad practice. It works much better if you add the radius as a blend on your extruded model. There you can use the same expression to configure them with your journal. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2...
  11. NutAce

    Load customize Drafting templates NX12

    The Template folder should be correctly defined in your env.dat file where the UGII_TEMPLATE_DIR variable points to correct path. NX knows then where to look for the pax file and the templates. Your pax file needs to have the correct template names so NX knows which one to use when creating the...
  12. NutAce

    UG NX rotate and Zoom Lags

    Go to the Visualization Preferences and have a look at the settings over there. On the Tab "Large Model" you can start with setting the Fixed Frame rate. On General Graphics you should disable translucency and Line Antialiasing. Other settings you just have to play around with. Ronald van den...
  13. NutAce

    UG/NX 12 Section Line Associated Loss On Drawing?

    With "View dependent edit" you can make only those needed hidden lines visible. Doing it like this the other hidden lines can be switched off again. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12...
  14. NutAce

    NX11 Hole Table Issue

    Did you try the same pattern but with one hole size? Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11
  15. NutAce

    NX1892 : How to make NX to connect to central Material library

    Hi, I am not quite sure if it is supposed to work like this (That you, as a normal user are allowed to add materials to a Site material list) In our company there is a special department responsible for the materials used inside the company (as with most other large companies). They do not have...
  16. NutAce

    NX1892 : How to make NX to connect to central Material library

    From earlier NX versions, there is a setting in the Customer defaults. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11
  17. NutAce

    NX12 Tool Bar Short-Cut Keys

    First I would check where the UGII_USER_PROFILE_DIR variable is pointing to. Check if you have write access to that folder. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11
  18. NutAce

    Importing parasolid model into NX from Creo/ProE - how to change ProE 'split cylinders' into holes?

    Lol. yes that one has been there for a looooong time already. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11
  19. NutAce

    Part file size.

    Or you remove the Parameters from the feature. Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11
  20. NutAce

    Importing parasolid model into NX from Creo/ProE - how to change ProE 'split cylinders' into holes?

    The NX installation has a translator for ProE... did you try this? Ronald van den Broek Senior Application Engineer Winterthur Gas & Diesel Ltd NX9 / TC10.1.2 Building new PLM environment from Scratch using NX12 / TC11