  1. engfir

    underground pipelne

    could you tell me the distance in the above ground pipeline
  2. engfir

    water pipeline

    i was constructed awater pipeline diamter : 3" material : astma106 after 1.5 year the flow rate was decreased when i inspected it i found that it internal diameter was decreaded because of corroson i thought to construct anew pipeline but i am confuced which material to use galvanied steel...
  3. engfir

    underground pipelne

    all what you say is right but i want the standard of culvert to read it
  4. engfir

    underground pipelne

    cause i want to calculate the width of culvert
  5. engfir

    pump material

    around 100 c
  6. engfir

    underground pipelne

    thank you could you tell me what is the refrence u used so i could use it in any future question
  7. engfir

    pump material

    I want to ask about appropriate centrifugal pump material for pump the liquid will be waste water high temperature it contains a percentage acids
  8. engfir

    PONTOONS DESIGN OF EXTERNAL FLOATING ROOF

    me too i need information for design internal floating roaf
  9. engfir

    underground pipelne

    i found the standard for buried pipelines not culvert only i wonder what is refrence for pipeline in culvert
  10. engfir

    underground pipelne

    I am sorry but i don't know if there is a standard for pipeline in culvert which define distance These is my first time to construct pipeline in culvert i need to define the distance between pipeline but i don't how cause i don't have arefrence to read
  11. engfir

    underground pipelne

    it will be in culvert i know thickness and weight and diameter but i need equation that calculate safe distance in culvert
  12. engfir

    underground pipelne

    is there is asafe distance between two parallel pipeline is it differant between above ground and above ground pipeline
  13. engfir

    underground pipelne

    i have sveral pipelines that must pass underground of the highway the pipelines are for different product with different diameters 1_ steam pipeline 2- saturated water 3- jet 4- fire fighting pipeline 5- oil pipeline i don't know how to calculate safe distance between these pipelines so please...
  14. engfir

    pump inlet

    iam installing anew horizontal pump that the configuration on inlet as 1- gate valve (isolation) 2- striner ( mesh 100) 3- pump what is the minmum allowable distance between them
  15. engfir

    pump inlet

    i want to ask what is allowable length between horzontal pumo and it screen filter mesh 100 i want to ask what is allowable length between screen filter mesh 100 and it sisolation valve on inlet of pump
  16. engfir

    sizing condensate tank

    I would like to add that the tank capacity is around 9 m3 The temperature is around 95 c So I want the equation of high temperature design cases Also if you could give me the equation of design Semitic load Thanks for your help
  17. engfir

    sizing condensate tank

    I want to design tank That will contain saturated water flash steam The tank is vented to atmosphere I don't know if I will use a vertical rectangular tank or horizontal cylindrical tank The tank will be equipped with pump that will work with level switch installed on tank level I wish to...