  1. wag2483

    column k value

    Got it. Thank you!
  2. wag2483

    column k value

    Attached is a PE sample problem. The answer is B, not following why. All else equal wouldn't the pin/brace direction have k=1.0, while the pin/moment direction has k=0.7. Thus column capacity is less in the brace (north-south) direction and will...
  3. wag2483

    Column live load reduction

    If a 1st story column in a multi story qualifies for live load reduction, is roof live load reduction also applied or is the roof reduction treated as any regular floor? The latter is what I've noticed in examples, yet the first sentence of asce 4.7.1 states except roof uniform live loads Also...
  4. wag2483

    Submerged plate design

    In lieu of stop logs a contractor has proposed a plate to retain water. The plate would drop into vertical notches that were originally cast into an 8' x 8' concrete conduit. The design approach is to treat the plate in horizontal strips acting simply supported. To be determined, but anticipated...
  5. wag2483

    Bracket for guardrail post to channel web

    Pham - was specifically referring to the attached photo and observed other similar connections.
  6. wag2483

    Bracket for guardrail post to channel web

    Is there a standard side mount bracket detail or product between a channel web and round post for an industrial guardrail? Each as-built I've seen has a mount on top flange of channel, acting as a pin connection, not meeting IBC lateral load criteria. Thank you
  7. wag2483

    All bolted single-angle connection

    The example goes on to check flexure for one of the angles legs. The calculation uses Zx from the property table, however the Zx neutral axis is about one leg vertical and another horizontal. The connection is positioned with both legs vertical. Why is Zx not calculated like a vertical plate for...
  8. wag2483

    All bolted single-angle connection

    Thanks, that makes sense. Looks like shear does barely govern over both bearing edge and spacing in this case. AISC Design example version 14 does have an all-bolted single angle example problem, where oddly enough bearing governs. Naturally they threw themselves a softball and used a C value...
  9. wag2483

    All bolted single-angle connection

    Requesting some direction on identifying the Lc dimension for Bearing strength at bolt holes for in plane eccentricity. Using the 13th edition of AISC. Spec J10(a) notes independent of the direction of loading however Lc is defined just below as clear distance in the direction of force...
  10. wag2483

    sistering joists/stair framing

    Thanks, everyone. Attached is a sketch for further clarity
  11. wag2483

    sistering joists/stair framing

    Hey folks, I have an old house, single header and trimmers around the stair opening, the age is beginning to show. I considered sistering the joists and reviewed a few previous posts on this site regarding that topic. Given that NDS doesn't have provisions for sistering and the existing cross...