Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. sham96

    230VAC Contactor (24VDC Coil) wiring with 24VDC Proximity Sensor

    Hello Everyone! I am trying to figure out how to connect a 24VDC NPN Proximity Sensor to a 230VAC contactor with 24VDC coil. I need the contactor to turn ON/OFF with the sensor signal. I have followed the below wiring diagram but my attempts have been unsuccessful (The contactor does not switch...
  2. sham96

    Forward and Reverse VFD Wiring for Lift Application

    @Mr.Che : Sorry for my delay in updating(We had to get down the Emergency Latching/DPDT switches)but we were finally able to test your circuity and it worked beautifully and exactly according to our requirements! The lift does not move beyond the limit switches at A and B even when the OP...
  3. sham96

    Forward and Reverse VFD Wiring for Lift Application

    @waross: VFD Model- BEDFORD B503 Series https://files.engineering.com/getfile.aspx?folder=edcf6760-1a00-4553-b27f-85b571842d9c&file=B503_english_manualV1.0.0-20130402.pdf.pdf
  4. sham96

    Forward and Reverse VFD Wiring for Lift Application

    @davidbeach: Each VFD provides several different control modes that enable us to control its operation via its external terminals, For e.g 2-Wire, 3-Wire Control. I have used 3-Wire Control mode where signals such as FORWARD Run, REVERSE Run are given through momentary NO push buttons and STOP...
  5. sham96

    Forward and Reverse VFD Wiring for Lift Application

    Thanks so much for the feedback everyone, There’s a few questions to be answered so i will get to that first! According to the wiring I had done, the Normally-Closed limit switches at point A and B only serve the sole purpose of stopping the Lift movement (deactivate ALL signals) regardless of...
  6. sham96

    Forward and Reverse VFD Wiring for Lift Application

    Hello Everyone! I have an application where I use a VFD to control a 3-Phase AC motor. The application involves a lift which is used to transfer a load from point A to B and after unloading the lift needs to return from Point B to A. I currently am using two Normally-Open push buttons for...
  7. sham96

    Forward / Reverse Switching of Single-Phase Motor

    Wow Mr.Che! I was really hoping that you’d see this thread since you helped me last time too to figure out the wiring for the three-wire motor! It was your diagram that I had attached on this thread and this has got to be my lucky day [2thumbsup]. Thank you so much for taking your time and...
  8. sham96

    Forward / Reverse Switching of Single-Phase Motor

    Something like the following diagram: Yes @waross agree with you! Just a bit confused on how I should wire the white and black wires since they change in both diagrams.
  9. sham96

    Forward / Reverse Switching of Single-Phase Motor

    Thank you for sharing this valuable thread @itsmoked. My motor, however, does not have U,V,W windings. It is a very small motor (~25W) and I want to control its direction using a single switch. Any feedback on how I can do this based on the wiring diagram?
  10. sham96

    Forward / Reverse Switching of Single-Phase Motor

    Hello Everyone! I have a single-phase motor which I want to run in forward and reverse directions using a DPDT switch. The wiring diagram for both CW and CCW is shown below: Could someone please tell me how I should do this? Any help is appreciated!
  11. sham96

    4-Pole Single-Phase AC Motor Wiring

    @waross thank you for your kind help! I found a wiring diagram through their website that matches the motor wire colors and this was the only one I could find. Is this diagram consistent with your theory? If so, I will try to implement it!
  12. sham96

    4-Pole Single-Phase AC Motor Wiring

    Hello Everyone! We recently purchased a Speed-Control Single-Phase AC induction motor with the following specs: Model : 51K40RGN-C (Oriental Motor) Rated Power : 40W Rated Voltage : 200V No. Of Poles : 4 Rated Current : 0.5A uF : 2.5 This motor consists of four wires (blue,black,yellow and...
  13. sham96

    Speed Control of Single-Phase Induction Motor

    @waross Sir I can confirm your description of this motor. As you stated this is a reversible motor and the direction of rotation can be changed with a single switch(Attached the wiring diagram below) www.jaaris.com
  14. sham96

    Speed Control of Single-Phase Induction Motor

    small update : I contacted the Oriental Motor USA technical division and they informed me that I cannot control the speed of this particular model. There are however other speed-control models available. @waross : definitely will use @itsmoked post as a guide for all future purchases! :)
  15. sham96

    Speed Control of Single-Phase Induction Motor

    Thank you all for your great feedback! I'm learning alot via this platform [smile]. We are currently using this motor for a project which requires this motor to run at a lower speed. This motor comes equipped with a gearbox (Model: 4GK25K) but the speed still is very high. I was hoping for a...
  16. sham96

    Speed Control of Single-Phase Induction Motor

    @3DDave Sir from what I know it is not advisable to use a single-phase VFD for single-phase IM since these motors are wound differently than a 3 phase motor. In order to use a single phase motor with a VFD, the motor must be inverter grade, which means paying to have the existing motor rewound...
  17. sham96

    Speed Control of Single-Phase Induction Motor

    Oh alright Sir, That is indeed a bummer! Thanks for your feedback :)
  18. sham96

    Speed Control of Single-Phase Induction Motor

    Hello Everyone! I have a single-phase reversible induction motor with the following specifications: Model : 4RK25GK-AUL Rated Power: 20W Rated Voltage: 100V Rated Current: 0.57A uF : 8 I am looking for a way to control its speed. Can I use a dimmer switch or a fan-speed control switch to do...
  19. sham96

    Type of Contactor for Direction Change of Single-Phase IM

    Thank you all for your kind responses! I was in the mindset that only contactors can be used to reverse the direction of motor rotation but now I have decided to use a DPDT switch :) Very grateful for all the help, kind regards and stay safe!
  20. sham96

    Type of Contactor for Direction Change of Single-Phase IM

    Dear Sir, Thank you for your response! The Single-Phase IM is a capacitor start motor and I have attached both the motor nameplate and wiring diagram photos. Can I wire this motor to rotate in both...