Hello, I have a patran model and have assigned the subcases and sent them to Nastern for analysis.
I have imported the results from the.XDB file in Partan for review, and I found a new subcase has been generated with the same ID, but the software adds SC before it.
For example, I defined a...
As we know, if we want to adopt the direct analysis method in steel design, there are some steps to fulfill the code requirement.
1: reducing stiffness by 0.8
2: Assign the slenderness factors K major and K minor for all members by 1.00.
3: applying the notional load as a percentage of gravity...
i would recommended to you a software named (CFS) cold formed section , i use it everyday in my cold formed design , its easy to use and report is very good and satisfied .