Dear acfm,
A tip speed of min. 15 m/s is required to obtain a stable liquid ring (when using water or similar density, with atmospheric discharge pressure and for 50–100mbarA suction pressure).
Smaller liquid ring vacuum pumps are designed to be direct driven with tip speeds of 20-22m/s for...