  1. simplemath2

    Finite Element calculation for floating roof

    Geoff13 - a lot of your question can be answered by boundary condition used in floating case: "When the roof is floating on the process fluid, the deck stays level with respect to the XY plane. Based on that, in order to bound the model in the Z direction, displacement of the deck. nodes are...
  2. simplemath2

    Condensation of moisture outside the double-walled LNG storage tank

    possibly perlite void is formed around that place. You can insert a camera thu perlite fill nozzle to verify. How long have this tank operated? If it is less than a year from construction, perlite void is a high possibility due to inadequate perlite vibration.
  3. simplemath2

    maximum sag before knuckling pipe (lifting 40m long pipe)

    if you lifting point is above the CG, isn't pipe in tension?
  4. simplemath2

    code requirement for leak testing of steam heat trace pipe

    bimr is correct. Steam pipe with pressure this low may qualify Cat D service to do initial service leak test in lieu of hydro with customer approval.
  5. simplemath2

    PVC - Solvent Cemented Joint Strength / Failure Modes

    Agree with moltenmetal on size of PVC pipe. I would not use PVC over 4" because solvent cemented is less reliable exceeding 4" and HDPE and fusion connection should be used. What is support span of pipe? If not continuous supported, support span shall be calculated and in my experience, it is...
  6. simplemath2

    Winterizing tank appurtenances

    David - You may attract more replies if more information such as location can be provided. Gasket typically is not part of winterizing plan since the material shall be good for MDMT.
  7. simplemath2

    API 650 bitiminous sand mixture for ring wall with sand filled or concrete floor

    A lot of practical knowledge here. Thanks Duwe6 for posting this.
  8. simplemath2

    computer programs

    David- I am with you totally on the good of mathcad and the bad of prime. I was a Mathmatica user in university and I will have a look into how it is today.
  9. simplemath2

    Software for Managing Line Lists

    Jerry: You may look into excel shared workbook function. Save excel in a shared drive and several people can work and save at the same time. I am using a excel like that not for line list but for project time log. For user right control, you may need to use a procedure in VBA . I would think...
  10. simplemath2

    pressure and flow in fluid a branch?

    is this something college class homework?
  11. simplemath2

    Pipe support questions

    You may use ASME B31.3 319.4.1 to rule out the stress analysis requirement. It may end up same as equation provided by pennpiper. But when someone has to approve your design, it may helpful behind a code.
  12. simplemath2

    Foundation Venting for Hot Tank

    Pipe is needed for prevention of soil dryness resulting from heating and water loss.Geotech engineer shall be able to tell max temperature bottom of foundation. Then you can tell if sand insulation is adequate. The pipes per your description feels like not for passive cooling.
  13. simplemath2

    Foundation Venting for Hot Tank

    Radially buried vent pipe with riser to remove heat by natural convection.
  14. simplemath2

    ASTM/AWWA Type pipe material used in AWWA water tank

    Thanks JStephen and IFRs. JStephen: Coating is taken care by 3rd party. I do not know much about it. I would specify the same if I do it. IFRs: You are right on AWWA quotation regarding pipe use. However, D-100 05 2.1.1 does not rule out using other pipe material. "Steel pipe shall conform to...
  15. simplemath2

    ASTM/AWWA Type pipe material used in AWWA water tank

    Pretty good size of pipe inside AWWA water tank serve to diffuse and minimize mixing. Size is 30" to 40". tank is 40ft and atm pressure. So max pressure pipe will see is hydraulic head by assuming no water hammer load. Water will diffuse at close to working level so pipe will be riser close to...
  16. simplemath2

    Agitater

    ione: Good doc. A star for you.
  17. simplemath2

    steam pressure conversion

    A little deviation from original post. I often encountered refinery steam line marked as 50 pound steam. General speaking, Does it mean gauge pressure(50psig) or absolute pressure(50psia)? Thanks. Yung
  18. simplemath2

    Drain pipe design

    Any general practice in sizing drain piping is highly appreciated.
  19. simplemath2

    Drain pipe design

    I am assigned to design a spill way for LNG tank. It is to drain LNG in case flange failure. While sizing the vertical drain piping, I was told to use self-venting design which limites froude # <0.3. My questions are: 1. If design for full flow(froude # =0.8), is it acceptable? what bad will...