Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. RFreund

    Punching shear on S.O.G.

    So the Shentu method is based on testing, I believe, by the Storage Equipment Manufacturers Association and The Second Research and Design Institute of Chinese Mechanical Industrial Department. I've tried to reach out for this testing and from what I've gathered, it doesn't exist, or no one can...
  2. RFreund

    Unrestarined Cold Form Design for Monoslope Roof

    Agreed. And to clarify the X-bracing down the center in those drawings was your diaphragm truss if I remember correctly.
  3. RFreund

    Unrestarined Cold Form Design for Monoslope Roof

    Typically, the standing seam roof is designed to float. You really shouldn't count on it for bracing or for diaphragm action (unless it's a through fastened system or has testing done per S908). A couple of good documents are AISI D111 (https://scholarsmine.mst.edu/ccfss-aisi-spec/235/) and the...
  4. RFreund

    Residential Basement Excavation Bracing and minimum lateral earth pressure

    Thanks for the response. I should have been clearer in my original post. The wall itself is a cantilever soldier pile wall. But my problem would still be the same. The cohesion is so high that I don't have any lateral earth pressure, see below. I'm wondering what you would use as a minimum:
  5. RFreund

    Residential Basement Excavation Bracing and minimum lateral earth pressure

    I suppose my main question is, what do you use as a "minimum lateral earth pressure" when designing temporary excavation bracing. This project involves excavation bracing for an 11' deep basement for a new home. The basement is fairly tight to the lot lines, but the neighboring structures are...
  6. RFreund

    LEDGERS ON ICF WALLS

    Can you design the bolts in bending (as a cantilever)?
  7. RFreund

    Wood truss moving bearing

    I usually see plywood/OSB gussets and adding members/bracing as needed. Here is an old article.
  8. RFreund

    Temporary Reinforced Concrete Pipe Support

    We need to excavate below an existing RCP to install a new diversion box. The pipe is active and filled with water. The contractor is asking to support the RCP via option-1 and option-2 below. Typically, we completely support the pipe with straps and beams above in this case. We can do that...
  9. RFreund

    Conduit in PT Slab

    We have some general notes and a detail regarding conduit running horizontally through concrete slabs. One of those notes is to provide rebar perpendicular to pipe embedments. This is in accordance with ACI 318-19 section 20.6.4 which says to provide at least 0.002 x area of concrete normal to...
  10. RFreund

    Soldier Pile Design with Cohesion

    Thanks both of you. I was a little too deep in the trees and missed the forest. As you both mentioned. Start with per length of wall, then apply the trib width. I think some fairly high cohesion values were throwing me off. Which is a topic of a different conversation... Thanks again
  11. RFreund

    Soldier Pile Design with Cohesion

    I am checking a soldier pile design with 'mixed soils' (i.e. uses friction angle and cohesion). The way I typically apply lateral earth pressures to the pile is to multiple the active forces above the dredge line by the pile spacing and the passive & active forces below the dredge line by the...
  12. RFreund

    Convert 10 minute mean wind velocity to 3-sec gust

    Is it possible to convert 10-minute mean wind velocity to 3-sec gust? Or even fastest mile? Thanks!
  13. RFreund

    Shear reinforcement in two way slab

    Good follow up. I accept this conclusion. Thanks.
  14. RFreund

    Shear reinforcement in two way slab

    After some outside consultation, I suppose this is "why" they are not the same... The strips are overlapping and essentially integrating the same stresses over the same areas (see image below). So it is "double counting" in my mind, but what should the required area of steel actually be? The...
  15. RFreund

    Shear reinforcement in two way slab

    Here is why I struggle with the FEM results and end up finding myself in the "double counting the load" camp... If I stay with SticksandTriangles example and I were to look break up the slab into four beams along the column lines and design for tributary load. I would get 1/2 the shear that I...
  16. RFreund

    Fastening Aluminum Cladding to Building Substrate - Dissimilar Metals and Galvanic Reaction

    I've gone down a hole and am trying to come out the other side with understanding "best practices" for fasteners used in exterior applications (not necessarily in a marine environment. Generally speaking I'm referring to aluminum cladding components (i.e. clip angles) that are part of a...
  17. RFreund

    Steel Stud Deflection Track Gap

    Take a look at this system if you need to achieve a specific fire rating a need space for deflection over 2": Deep leg tracks by "Fire Trak". http://www.firetrak.com/fire-trak.html
  18. RFreund

    Calculating the Flexural Strength of Granite Facade Panel

    @jjl317 - I think you're right. It looks like I mistakenly pulled a value from porcelain tile.
  19. RFreund

    Non-Loadbearing CFM walls as LFRS - Part 2

    You know I almost always used CFS (cold formed steel), but it seems like all specs/Revit is setup as "CFM" or "CFMS" cold formed metal and cold formed metal stud.

Part and Inventory Search